Brand: Raritan | Category: Rack PDUs
SKU: RARI-PX45906R | Part #: PX4-5906R | MPN: PX4-5906R
Contact for Pricing — Request a Quote
The Raritan PX4-5906R is a 3-phase switched rack PDU delivering up to 17.3kW of managed power distribution for high-density data center environments. Built on Raritan's seventh-generation iX7 controller, the unit provides per-outlet switching, real-time power metering at the inlet, outlet, and phase levels, and environmental monitoring support — enabling granular visibility and remote control across every receptacle in the rack. The PX4 platform communicates natively over dual Ethernet with support for IPv4, IPv6, SNMP v1/v2c/v3, Modbus TCP, REST API, and HTTPS, integrating cleanly into enterprise DCIM ecosystems including Raritan's own PowerIQ and dcTrack platforms.
The PX4-5906R operates on a 3-phase input drawn from a 380–415V AC, 50/60 Hz feed via a IEC 309 (IEC 60309) 3-phase 32A input connector, distributing power across a high-density outlet bank of 42 × C13 and 6 × C15 receptacles. Per-outlet switching allows remote power cycling and sequenced startup or shutdown of individual servers, network devices, or storage nodes without physical access to the rack — a capability critical in lights-out and remote colocation scenarios. Outlet-level current and energy metering with configurable alert thresholds supports proactive capacity management and helps prevent circuit overloads.
Designed with the demands of AI/ML compute clusters, hyperscale edge nodes, and high-density virtualization racks in mind, the PX4-5906R mounts in a 0U vertical form factor, preserving rack unit space for revenue-generating compute. An integrated environmental sensor bus supports the connection of Raritan's DPX and SensorHub accessories for temperature, humidity, airflow, and door contact monitoring. Secure access is enforced through role-based access controls, TLS 1.2/1.3 encryption, and certificate management, satisfying the audit and compliance requirements common to financial services, healthcare IT, and government data center operators.
| Manufacturer | Raritan |
| Manufacturer Part Number | PX4-5906R |
| Series | PX4 |
| Controller | iX7 (7th Generation) |
| Form Factor | 0U Vertical |
| Phase Configuration | 3-Phase |
| Maximum Power | 17.3 kW |
| Input Voltage | 380–415V AC, 3-Phase |
| Input Frequency | 50/60 Hz |
| Input Connector | IEC 60309 32A 3-Phase |
| Total Outlets | 48 |
| Outlet Types | 42 × IEC 60320 C13, 6 × IEC 60320 C15 |
| Outlet Switching | Per-Outlet Switched |
| Metering Granularity | Inlet, Phase, and Per-Outlet |
| Network Interfaces | Dual Gigabit Ethernet (RJ-45) |
| Supported Protocols | SNMP v1/v2c/v3, Modbus TCP, REST API, HTTPS, IPv4, IPv6 |
| Environmental Sensor Bus | Raritan DPX / SensorHub compatible |
| Security | Role-Based Access Control, TLS 1.2/1.3, Certificate Management |
| DCIM Compatibility | Raritan PowerIQ, dcTrack |
Available from Omnixon Global. Submit an RFQ and our team will confirm configuration and availability for your order.
| Brand | Raritan |
| Category | Rack PDUs |
| SKU | RARI-PX45906R |
| Part Number | PX4-5906R |
| Condition | New |
| Manufacturer Part Number | PX4-5906R |
| Series | PX4 |
| Controller | iX7 (7th Generation) |
| Form Factor | 0U Vertical |
| Phase Configuration | 3-Phase |
| Maximum Power | 17.3 kW |
| Input Voltage | 380–415V AC, 3-Phase |
| Input Frequency | 50/60 Hz |
| Input Connector | IEC 60309 32A 3-Phase |
| Total Outlets | 48 |
| Outlet Types | 42 × IEC 60320 C13, 6 × IEC 60320 C15 |
| Outlet Switching | Per-Outlet Switched |
| Metering Granularity | Inlet, Phase, and Per-Outlet |
| Network Interfaces | Dual Gigabit Ethernet (RJ-45) |
| Supported Protocols | SNMP v1/v2c/v3, Modbus TCP, REST API, HTTPS, IPv4, IPv6 |
| Environmental Sensor Bus | Raritan DPX / SensorHub compatible |
| Security | Role-Based Access Control, TLS 1.2/1.3, Certificate Management |
| DCIM Compatibility | Raritan PowerIQ, dcTrack |