Schneider Electric Galaxy VL 200kVA UPS

Schneider Electric Galaxy VL 200kVA UPS

Brand: Schneider Electric | Category: UPS & Power Protection

SKU: SCHN-GVL200K500NS | Part #: GVL200K500NS | MPN: GVL200K500NS

Contact for Pricing — Request a Quote

Request a Quote Contact Us

About the Schneider Electric Galaxy VL 200kVA UPS

The Schneider Electric Galaxy VL 200kVA UPS (GVL200K500NS) is a large-scale, modular three-phase uninterruptible power supply engineered for hyperscale data centers, large enterprise facilities, and mission-critical infrastructure requiring continuous, high-density power protection. Built on a scalable modular architecture, the Galaxy VL delivers online double-conversion topology that fully isolates connected loads from all input power anomalies including sags, surges, harmonics, and complete outages, ensuring clean and regulated output at all times. The system supports a power factor of 1.0 (unity), meaning the full 200kVA capacity is available as active power (200kW), eliminating the derating penalties common with older UPS designs.

A defining capability of the Galaxy VL platform is its Live Swap module design, which allows power and battery modules to be inserted or removed while the UPS remains fully operational and load-bearing—eliminating planned maintenance downtime and reducing operational risk in environments where availability is non-negotiable. The unit achieves up to 99% efficiency in ECO mode and up to 97% efficiency in double-conversion mode, directly reducing PUE and total cost of energy consumption at scale. The Galaxy VL also supports demand response participation, enabling facilities to respond to grid events without disrupting protected loads.

Designed for integration into modern data center power chains, the Galaxy VL 200kVA is compatible with EcoStruxure IT for remote monitoring, predictive analytics, and fleet management across distributed sites. Its wide input voltage window and configurable output voltage settings provide flexibility for diverse facility configurations. The unit supports both standalone and parallel redundant (N+1 and 2N) deployments, scaling capacity and redundancy to match the demands of hyperscale compute, colocation, financial services infrastructure, and large healthcare or government data center environments.

Ideal for

  • Hyperscale and colocation data center power protection requiring scalable, high-density three-phase UPS infrastructure with minimal planned downtime
  • Enterprise data centers seeking to reduce PUE and energy costs through high-efficiency double-conversion power protection at 200kW effective output
  • Mission-critical facilities requiring N+1 or 2N parallel redundancy architectures with Live Swap serviceability to eliminate maintenance windows
  • Financial services and trading environments demanding zero-tolerance for power interruptions and full isolation from grid-side disturbances
  • Healthcare and government data centers requiring long-duration battery runtime configurations with modular battery expansion capability
  • Large enterprise IT consolidation projects integrating UPS management into EcoStruxure IT for centralized monitoring, predictive maintenance, and DCIM ecosystem alignment

Technical specifications

ManufacturerSchneider Electric
Manufacturer Part NumberGVL200K500NS
UPS TopologyOnline Double-Conversion (VFI, Voltage and Frequency Independent)
Phase Configuration3-phase input / 3-phase output
Output Power Capacity200 kVA / 200 kW
Output Power Factor1.0 (unity)
Nominal Input Voltage400V AC (three-phase)
Input Voltage Range160–294V AC (per phase)
Nominal Output Voltage400V AC (three-phase)
Output Voltage THDLess than 1% (linear load)
Input Frequency Range45–65 Hz
Output Frequency50 or 60 Hz ± 0.1 Hz (inverter mode)
Efficiency (Double-Conversion Mode)Up to 97%
Efficiency (ECO Mode)Up to 99%
Operating ModeDouble-Conversion, ECO Mode, Demand Response
ModularityHot-swappable / Live Swap power and battery modules
ScalabilityParallel operation supported for N+1 and 2N redundancy configurations
Communication InterfacesNetwork Management Card slot; EcoStruxure IT compatible
Operating Temperature0–40°C
Standards ComplianceIEC 62040-1, IEC 62040-2, IEC 62040-3 (VFI-SS-111)
Form FactorTower / Free-standing modular cabinet
Protection FeaturesInput surge protection, output short-circuit protection, overload protection, battery protection

Available from Omnixon Global. Submit an RFQ and our team will confirm configuration and availability for your order.

Technical Specifications

BrandSchneider Electric
CategoryUPS & Power Protection
SKUSCHN-GVL200K500NS
Part NumberGVL200K500NS
ConditionNew
Manufacturer Part NumberGVL200K500NS
UPS TopologyOnline Double-Conversion (VFI, Voltage and Frequency Independent)
Phase Configuration3-phase input / 3-phase output
Output Power Capacity200 kVA / 200 kW
Output Power Factor1.0 (unity)
Nominal Input Voltage400V AC (three-phase)
Input Voltage Range160–294V AC (per phase)
Nominal Output Voltage400V AC (three-phase)
Output Voltage THDLess than 1% (linear load)
Input Frequency Range45–65 Hz
Output Frequency50 or 60 Hz ± 0.1 Hz (inverter mode)
Efficiency (Double-Conversion Mode)Up to 97%
Efficiency (ECO Mode)Up to 99%
Operating ModeDouble-Conversion, ECO Mode, Demand Response
ModularityHot-swappable / Live Swap power and battery modules
ScalabilityParallel operation supported for N+1 and 2N redundancy configurations
Communication InterfacesNetwork Management Card slot; EcoStruxure IT compatible
Operating Temperature0–40°C
Standards ComplianceIEC 62040-1, IEC 62040-2, IEC 62040-3 (VFI-SS-111)
Form FactorTower / Free-standing modular cabinet
Protection FeaturesInput surge protection, output short-circuit protection, overload protection, battery protection