The Eaton 93PM is a transformerless, double-conversion (online) three-phase UPS engineered for high-density enterprise data centers and critical power infrastructure. Operating at unity power factor (1.0) on both input and output, the 100 kW configuration (part number 93PM-100) delivers true online UPS protection with near-zero transfer time, ensuring continuous, conditioned power to sensitive IT loads. Its modular power module architecture supports concurrent maintainability, allowing individual power modules to be serviced or replaced without interrupting the protected load—a key requirement for always-on data-center environments.
Built around an advanced IGBT rectifier and inverter topology, the 93PM achieves up to 96% efficiency in double-conversion mode and up to 99% efficiency in Energy Saver System (ESS) mode, significantly reducing heat dissipation and cooling overhead in the power room. The unit supports wide input voltage and frequency acceptance windows, accommodating generator power and utility fluctuations without switching to battery. Communication interfaces include dry contacts, USB, RS-232, and an option for SNMP/Web cards, enabling deep integration with building management systems (BMS), DCIM platforms, and remote monitoring infrastructure.
The 93PM 100 kW model is scalable within a modular framework, allowing capacity to be increased incrementally as data-center load grows, protecting capital investment and simplifying future expansion planning. It supports multiple battery configurations including VRLA and lithium-ion battery cabinet options, and the front-access design suits both raised-floor and slab installations. With a compact footprint optimized for high-power-density deployments, the 93PM is widely specified for enterprise server rooms, colocation facilities, financial services data centers, healthcare IT infrastructure, and industrial control environments requiring uninterrupted, high-quality power.
| Manufacturer | Eaton |
| Manufacturer Part Number | 93PM-100 |
| UPS Topology | Double-conversion (online), transformerless |
| Output Power Capacity | 100 kW / 100 kVA |
| Output Power Factor | 1.0 |
| Input Voltage (Nominal) | 400 V three-phase (3-wire + PE or 4-wire + PE) |
| Output Voltage (Nominal) | 400/230 V three-phase |
| Input Frequency | 45–65 Hz (auto-sensing) |
| Output Frequency | 50 or 60 Hz ± 0.1 Hz (inverter mode) |
| Double-Conversion Efficiency | Up to 96% |
| Energy Saver System (ESS) Efficiency | Up to 99% |
| Input Power Factor Correction | Active PFC, >0.99 |
| Total Harmonic Distortion (input, THDi) | <3% at full linear load |
| Output Voltage Distortion (THDv) | <2% with linear load |
| Transfer Time (normal to battery) | 0 ms (true online, no transfer) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 5–95% non-condensing |
| Communication Interfaces | USB, RS-232, dry contacts; optional SNMP/Web card (Gigabit Network Card) |
| Scalability | Modular architecture; capacity expandable in the field |
| Battery Compatibility | VRLA (external battery cabinets); lithium-ion battery option available |
| Certifications | CE, IEC 62040-1, IEC 62040-3 (VFI-SS-111) |
| Form Factor | Floor-standing, front-access |
Available from Omnixon Global. Submit an RFQ and our team will confirm configuration and availability for your order.
| Brand | Eaton |
| Category | UPS & Power Protection |
| SKU | EATO-93PM100 |
| Part Number | 93PM-100 |
| Condition | New |
| Manufacturer Part Number | 93PM-100 |
| UPS Topology | Double-conversion (online), transformerless |
| Output Power Capacity | 100 kW / 100 kVA |
| Output Power Factor | 1.0 |
| Input Voltage (Nominal) | 400 V three-phase (3-wire + PE or 4-wire + PE) |
| Output Voltage (Nominal) | 400/230 V three-phase |
| Input Frequency | 45–65 Hz (auto-sensing) |
| Output Frequency | 50 or 60 Hz ± 0.1 Hz (inverter mode) |
| Double-Conversion Efficiency | Up to 96% |
| Energy Saver System (ESS) Efficiency | Up to 99% |
| Input Power Factor Correction | Active PFC, >0.99 |
| Total Harmonic Distortion (input, THDi) | <3% at full linear load |
| Output Voltage Distortion (THDv) | <2% with linear load |
| Transfer Time (normal to battery) | 0 ms (true online, no transfer) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 5–95% non-condensing |
| Communication Interfaces | USB, RS-232, dry contacts; optional SNMP/Web card (Gigabit Network Card) |
| Scalability | Modular architecture; capacity expandable in the field |
| Battery Compatibility | VRLA (external battery cabinets); lithium-ion battery option available |
| Certifications | CE, IEC 62040-1, IEC 62040-3 (VFI-SS-111) |
| Form Factor | Floor-standing, front-access |
The Eaton 93PM 100kW UPS delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
The Eaton 93PM 100kW UPS delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
The Eaton 93PM 100kW UPS delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
Key specifications for the Eaton 93PM 100kW UPS: new condition; manufacturer Eaton; manufacturer part number 93PM-100; ups topology Double-conversion (online), transformerless; output power capacity 100 kW / 100 kVA; output power factor 1.0; input voltage (nominal) 400 V three-phase (3-wire + PE or 4-wire + PE). Manufacturer part number 93PM-100. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.
Key specifications for the Eaton 93PM 100kW UPS: new condition; manufacturer Eaton; manufacturer part number 93PM-100; ups topology Double-conversion (online), transformerless; output power capacity 100 kW / 100 kVA; output power factor 1.0; input voltage (nominal) 400 V three-phase (3-wire + PE or 4-wire + PE). Manufacturer part number 93PM-100. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.