Brand: H3C | Category: UPS & Power Protection
SKU: UPS6000-A-40K | Part #: UPS6000-A-40K | MPN: UPS6000-A-40K
Contact for Pricing — Request a Quote
The H3C UPS6000-A 40kVA Modular UPS accepts three-phase 380/400/415 V AC input (three-phase four-wire) and delivers the same voltage specification at output, supporting input frequency ranges of 40–70 Hz with auto-sensing capability. This enterprise-grade uninterruptible power supply employs double-conversion online (VFI) topology to eliminate transfer time to battery—critical for mission-critical infrastructure where zero switching gaps are non-negotiable. Built on H3C's proven modular architecture, the UPS6000-A-40K features hot-swappable power modules and N+X redundancy support, allowing IT teams to scale capacity and fault tolerance without extended downtime.
The system delivers 40 kVA / 40 kW at 1.0 output power factor with up to 96% efficiency in double-conversion mode. An IGBT-based PWM rectifier achieves input power factor correction of ≥ 0.99 at full load while maintaining input total harmonic distortion (THDi) of ≤ 3%, protecting upstream distribution equipment from harmonic contamination. Output frequency synchronizes to input or runs free-running at 50 Hz or 60 Hz. H3C engineered this unit with forced air cooling and intelligent fan speed control to maintain stable operation across 0°C to 40°C environments. Communication options include RS-485, dry contacts, and optional SNMP network management card integration. Storage architects and IT procurement teams seeking modular, redundant power protection for data centers, server farms, and critical facilities will find the part number UPS6000-A-40K delivers enterprise resilience. Contact Omnixon Global to request a formal quote.
| Brand | H3C |
| Category | UPS & Power Protection |
| SKU | UPS6000-A-40K |
| Part Number | UPS6000-A-40K |
| Condition | New |
| Manufacturer Part Number | UPS6000-A-40K |
| Product Series | UPS6000-A |
| UPS Topology | Double-Conversion Online (VFI) |
| Rated Capacity | 40 kVA / 40 kW |
| Output Power Factor | 1.0 |
| Architecture | Modular, hot-swappable power modules |
| Redundancy Support | N+X modular redundancy |
| Input Voltage | 3-phase, 380/400/415 V AC (three-phase four-wire) |
| Output Voltage | 3-phase, 380/400/415 V AC (three-phase four-wire) |
| Input Frequency Range | 40–70 Hz (auto-sensing) |
| Output Frequency | 50 Hz or 60 Hz (synchronized to input or free-running) |
| Rectifier Technology | IGBT-based PWM rectifier |
| Input Power Factor Correction | ≥ 0.99 at full load |
| Input Total Harmonic Distortion (THDi) | ≤ 3% |
| System Efficiency | Up to 96% in double-conversion mode |
| Transfer Time (to Battery) | Zero (online double-conversion, no transfer gap) |
| Communication Interfaces | RS-485, dry contacts, optional SNMP network management card |
| Operating Temperature | 0°C to 40°C |
| Cooling Method | Forced air cooling with intelligent fan speed control |
| Form Factor | Modular rackmount / floor-standing cabinet |
| Compliance Standards | IEC 62040-1, IEC 62040-2, IEC 62040-3 |
Runtime is load-dependent. Most enterprise UPS at 50% load deliver 8-12 minutes battery on standard internal batteries. Add external battery packs (XL / RBC modules) to extend to 30-60 minutes if you need ride-through past short utility blips.
Yes — we ship the SNMP / Network Management Card (NMC) alongside the UPS, plus shutdown agents that integrate with VMware PowerChute, Veeam, NetApp ONTAP, and standard SNMP traps for orchestration platforms.
For Dubai and the wider UAE we offer installation, commissioning, and battery recycling per municipality regulations. For broader GCC we partner with local certified electricians and recyclers — included as an option in the quote.
Stocked tier (under 10 kVA): 5-7 business days. 10-20 kVA: 2-4 weeks typically. 20+ kVA modular / parallel systems: 6-10 weeks vendor-side, plus on-site commissioning scheduling. Real numbers quoted with every order.