The Vertiv Liebert EXM2 225kVA UPS (part number EXM2-225KVA-480V) accepts 480V three-phase input and delivers 480V three-phase output, supporting both 50/60 Hz auto-sensing input frequency with synchronized or free-running output frequency control. This enterprise-grade double-conversion online UPS system is engineered for data centers, mission-critical facilities, and IT infrastructure teams requiring continuous power protection without compromise.
Vertiv's EXM2 series combines industry-leading efficiency with robust fault tolerance. Operating at up to 96% efficiency in double-conversion mode and up to 99% in Economy/ECO mode, the unit minimizes operational costs while maintaining zero-millisecond transfer time to battery during utility interruptions. With an input power factor of ≥0.99 at full load and input current THD below 3% thanks to an IGBT active front-end rectifier, this UPS reduces strain on electrical infrastructure. The system supports 125% overload capacity for 10 minutes and 150% for 60 seconds, providing headroom for transient demand spikes. Static bypass with manual maintenance bypass ensures service continuity during routine maintenance. Network managers and IT procurement teams benefit from multi-protocol communication via SNMP, Modbus RTU/TCP, BACnet, and dry contacts, enabling seamless integration into existing management ecosystems. The EXM2-225KVA-480V delivers 225 kVA / 202.5 kW with a 0.9 output power factor, making it ideal for mixed resistive and reactive loads typical in enterprise environments.
For technical specifications, pricing, and availability of the EXM2-225KVA-480V, please submit a request for quotation (RFQ) through Omnixon Global.
| Brand | Vertiv |
| Category | UPS & Power Protection |
| SKU | EXM2-225KVA-480V |
| Part Number | EXM2-225KVA-480V |
| Condition | New |
| Model | Liebert EXM2 |
| Manufacturer Part Number | EXM2-225KVA-480V |
| UPS Topology | Double-Conversion Online (VFI) |
| UPS Capacity | 225 kVA / 202.5 kW |
| Output Power Factor | 0.9 |
| Input Voltage | 480V three-phase |
| Output Voltage | 480V three-phase |
| Input Frequency | 50/60 Hz (auto-sensing) |
| Output Frequency | 50 or 60 Hz (synchronized to input or free-running) |
| Input Power Factor | ≥ 0.99 at full load |
| Input Current THD | < 3% at full load (IGBT active front-end rectifier) |
| Efficiency (Online Mode) | Up to 96% in double-conversion mode |
| Efficiency (ECO Mode) | Up to 99% in Economy/ECO mode |
| Overload Capacity | 125% for 10 minutes; 150% for 60 seconds |
| Transfer Time (to Battery) | 0 ms (continuous online operation) |
| Transfer Time (to Bypass) | < 20 ms (static bypass) |
| Bypass | Static bypass with manual maintenance bypass |
| Communication Interfaces | SNMP, Modbus RTU/TCP, BACnet, dry contacts |
| Cooling Method | Forced air cooling with internal fans |
| Operating Temperature | 0°C to 40°C |
| Relative Humidity | 5% to 95% non-condensing |
| Standards Compliance | IEC 62040-1, IEC 62040-2, IEC 62040-3 (VFI-SS-111) |
Runtime is load-dependent. Most enterprise UPS at 50% load deliver 8-12 minutes battery on standard internal batteries. Add external battery packs (XL / RBC modules) to extend to 30-60 minutes if you need ride-through past short utility blips.
Yes — we ship the SNMP / Network Management Card (NMC) alongside the UPS, plus shutdown agents that integrate with VMware PowerChute, Veeam, NetApp ONTAP, and standard SNMP traps for orchestration platforms.