Eaton Rack PDU G4 Managed 0U

Eaton Rack PDU G4 Managed 0U

Brand: Eaton | Category: Rack PDUs

SKU: EATO-EMAB23 | Part #: EMAB23 | MPN: EMAB23

Contact for Pricing — Request a Quote

Request a Quote Contact Us

About the Eaton Rack PDU G4 Managed 0U

The Eaton Rack PDU G4 Managed 0U represents the latest evolution in Eaton's intelligent power distribution lineup, engineered specifically for high-density compute and storage racks where granular visibility and remote control of every outlet are mission-critical. The G4 architecture introduces a fully hot-swappable controller module, allowing IT and facilities teams to replace or upgrade the management brain of the PDU without powering down connected equipment — a breakthrough capability that eliminates planned maintenance windows at the outlet-management level. Per-outlet current metering with true RMS sensing provides real-time load data accurate to ±1% of full scale, enabling precise capacity planning and load balancing across phases and circuits.

Built around a zero-U vertical form factor, the G4 Managed PDU mounts flush in the rear of standard EIA-310 racks, preserving valuable rack unit space for revenue-generating equipment. The unit supports IPv4 and IPv6 dual-stack network management, integrates with leading DCIM platforms via Modbus TCP and SNMP v1/v2c/v3, and offers a RESTful API for seamless automation and orchestration workflows. Environmental monitoring inputs allow attachment of temperature and humidity sensors, correlating thermal data directly with power consumption metrics for holistic rack intelligence. Role-based access control, TLS 1.2/1.3 encryption, and local LCD display with physical outlet control buttons ensure both cybersecurity compliance and emergency manual override capability.

The G4 generation targets colocation providers, enterprise data centers, edge deployments, and hyperscale satellite sites operating high-density GPU compute clusters, storage arrays, and network switching infrastructure. Individual outlet switching with configurable power-on sequencing prevents inrush current spikes during mass restarts and enables remote power cycling of locked or unresponsive servers without a physical site visit. Integration with Eaton's Intelligent Power Manager (IPM) software and third-party platforms such as Vertiv Environet, Sunbird dcTrack, and Nlyte provides a unified power management pane across multi-vendor environments.

Ideal for

  • High-density GPU compute racks: Per-outlet switching and sequencing prevent inrush overloads during cluster restarts for AI/ML training workloads drawing sustained high amperage per server.
  • Colocation data centers: Tenant-level outlet grouping with role-based access allows colo operators to grant customers remote power-cycle capability over only their assigned outlets without exposing other tenants' infrastructure.
  • Edge and remote sites: Hot-swappable controller combined with remote outlet switching eliminates the need for on-site technicians to perform basic power-cycling tasks at unmanned edge locations.
  • Capacity planning and power optimization: True RMS per-outlet metering feeds DCIM platforms with accurate consumption data, enabling facilities teams to safely increase rack density without risking circuit overload.
  • Compliance-driven environments: SNMP v3 with AES encryption, TLS 1.3 management sessions, and audit-logged outlet events satisfy security and regulatory requirements in financial services, healthcare, and government data centers.
  • Planned maintenance without downtime: Hot-swappable controller module replacement during live operation allows firmware upgrades and hardware servicing of management electronics while connected servers remain fully powered.

Technical specifications

ManufacturerEaton
Product LineRack PDU G4 Managed
GenerationFourth Generation (G4)
Form Factor0U Vertical (Zero-U)
Input Voltage208V / 120V / 240V (model-dependent, single and three-phase variants available)
Input ConnectionNEMA L6-30P / IEC 60309 (model-dependent)
Maximum Input CurrentUp to 32A per phase (model-dependent)
Total Outlet CountUp to 24 outlets (model-dependent configuration)
Outlet TypesNEMA 5-20R, NEMA L6-20R, C13, C19 (model-dependent)
Per-Outlet MeteringTrue RMS current metering, ±1% accuracy of full scale
Per-Outlet SwitchingIndividual remote on/off/reboot control per outlet
Power-On SequencingConfigurable per-outlet delay (0–999 seconds) to manage inrush current
Controller ModuleHot-swappable controller with no power interruption to outlets during replacement
DisplayLocal LCD with navigation buttons; displays per-outlet and aggregate load data
Network InterfaceDual 10/100/1000BASE-T Ethernet (primary + failover)
Supported ProtocolsSNMP v1/v2c/v3, Modbus TCP, RESTful API, HTTPS, SSH, Syslog, NTP
IP Stack SupportDual-stack IPv4 and IPv6
Security FeaturesTLS 1.2/1.3, AES-256 encryption, role-based access control (RBAC), audit logging
Environmental Monitoring2× RJ45 sensor ports for Eaton-compatible temperature/humidity sensors
Software IntegrationEaton Intelligent Power Manager (IPM), Modbus TCP for DCIM, SNMP MIB for third-party platforms
Rack CompatibilityEIA-310 standard rack mounting, vertical 0U rear-mount with included hardware
Operating Temperature0°C to 45°C (32°F to 113°F)
Operating Humidity5% to 95% non-condensing
Regulatory ComplianceUL 60950-1 / UL 62368-1, CE, RoHS, FCC Part 15 Class A
Launch Period2025 Q2

Available from Omnixon Global. Submit an RFQ and our team will confirm configuration and availability for your order.

Technical Specifications

BrandEaton
CategoryRack PDUs
SKUEATO-EMAB23
Part NumberEMAB23
ConditionNew
Product LineRack PDU G4 Managed
GenerationFourth Generation (G4)
Form Factor0U Vertical (Zero-U)
Input Voltage208V / 120V / 240V (model-dependent, single and three-phase variants available)
Input ConnectionNEMA L6-30P / IEC 60309 (model-dependent)
Maximum Input CurrentUp to 32A per phase (model-dependent)
Total Outlet CountUp to 24 outlets (model-dependent configuration)
Outlet TypesNEMA 5-20R, NEMA L6-20R, C13, C19 (model-dependent)
Per-Outlet MeteringTrue RMS current metering, ±1% accuracy of full scale
Per-Outlet SwitchingIndividual remote on/off/reboot control per outlet
Power-On SequencingConfigurable per-outlet delay (0–999 seconds) to manage inrush current
Controller ModuleHot-swappable controller with no power interruption to outlets during replacement
DisplayLocal LCD with navigation buttons; displays per-outlet and aggregate load data
Network InterfaceDual 10/100/1000BASE-T Ethernet (primary + failover)
Supported ProtocolsSNMP v1/v2c/v3, Modbus TCP, RESTful API, HTTPS, SSH, Syslog, NTP
IP Stack SupportDual-stack IPv4 and IPv6
Security FeaturesTLS 1.2/1.3, AES-256 encryption, role-based access control (RBAC), audit logging
Environmental Monitoring2× RJ45 sensor ports for Eaton-compatible temperature/humidity sensors
Software IntegrationEaton Intelligent Power Manager (IPM), Modbus TCP for DCIM, SNMP MIB for third-party platforms
Rack CompatibilityEIA-310 standard rack mounting, vertical 0U rear-mount with included hardware
Operating Temperature0°C to 45°C (32°F to 113°F)
Operating Humidity5% to 95% non-condensing
Regulatory ComplianceUL 60950-1 / UL 62368-1, CE, RoHS, FCC Part 15 Class A
Launch Period2025 Q2

Frequently Asked Questions about Eaton Rack PDU G4 Managed 0U

What does the Eaton Rack PDU G4 Managed 0U do?

The Eaton Rack PDU G4 Managed 0U delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.

What are the headline specs of the Eaton Rack PDU G4 Managed 0U?

Key specifications for the Eaton Rack PDU G4 Managed 0U: new condition; manufacturer Eaton; product line Rack PDU G4 Managed; generation Fourth Generation (G4); form factor 0U Vertical (Zero-U); input voltage 208V / 120V / 240V (model-dependent, single and three-phase variants available); input connection NEMA L6-30P / IEC 60309 (model-dependent). Manufacturer part number EMAB23. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.