Brand: Vertiv | Category: Server Racks & Enclosures
SKU: VERT-XDU1350RD | Part #: XDU1350-RD | MPN: XDU1350-RD
Contact for Pricing — Request a Quote
The Vertiv Liebert XDU1350 Coolant Distribution Unit represents Vertiv's flagship thermal management solution for next-generation AI infrastructure, delivering up to 1350kW of liquid cooling capacity in a design purpose-built for direct-to-chip (D2C) and rear-door heat exchanger deployments. At its core, the XDU1350 operates as a facility-side-to-IT-side thermal bridge, accepting facility chilled water and conditioning it to precise supply temperatures required by cold plates mounted directly on GPUs, CPUs, and high-bandwidth memory modules. The unit integrates variable-speed pump redundancy, real-time flow metering, and precision temperature control to maintain coolant supply within tight tolerances regardless of instantaneous load fluctuations—critical for preserving performance and longevity of dense NVIDIA H100, H200, GB200, and AMD Instinct accelerator clusters.
| Manufacturer | Vertiv |
| Product Line | Liebert XDU |
| Model | XDU1350 |
| Maximum Cooling Capacity | 1350 kW |
| Cooling Method | Direct-to-chip (D2C) liquid cooling via cold plates; compatible with rear-door heat exchanger configurations |
| Coolant Type | Water or water-glycol mixture (facility-side); deionized water or dielectric fluid (IT-side) |
| Facility Water Inlet Temperature Range | 15°C to 45°C |
| IT-Side Supply Temperature Range | 20°C to 45°C (adjustable) |
| Maximum Flow Rate | Up to 600 L/min (facility-side); configurable IT-side distribution |
| Pump Configuration | Redundant variable-speed EC pump modules (N+1 standard, 2N optional) |
| Pump Redundancy | Hot-swappable pump modules with automatic failover, zero-interruption switchover |
| Working Pressure | Up to 10 bar (facility-side); up to 6 bar (IT-side distribution) |
| Leak Detection | Integrated distributed leak detection with zone isolation valves and automated shutdown triggers |
| Fluid Quality Monitoring | Inline conductivity, pH, and particulate sensing with BMS alarm integration |
| Management Protocols | Modbus TCP, BACnet/IP, SNMP v3, RESTful API |
| Local Interface | 7-inch color touchscreen HMI with trend logging and alarm history |
| Remote Monitoring | Compatible with Vertiv Environet Alert DCIM; third-party BMS integration supported |
| Power Supply | 400V / 3-phase / 50–60 Hz |
| Manifold Construction | 316L stainless steel primary manifold; high-pressure-rated flexible braided stainless distribution lines |
| Form Factor | Standalone floor-mounted unit with optional wall-mount bracket kit |
| Typical Physical Footprint | Approximately 800mm W × 1200mm D × 2000mm H (configuration-dependent) |
| Operating Ambient Temperature | 0°C to 45°C |
| Certifications | CE, UL, RoHS; IEC 62443 cybersecurity framework compliance for control interface |
| Launch Availability | Q4 2025 |
Available from Omnixon Global. Submit an RFQ and our team will confirm configuration and availability for your order.
| Brand | Vertiv |
| Category | Server Racks & Enclosures |
| SKU | VERT-XDU1350RD |
| Part Number | XDU1350-RD |
| Condition | New |
| Product Line | Liebert XDU |
| Model | XDU1350 |
| Maximum Cooling Capacity | 1350 kW |
| Cooling Method | Direct-to-chip (D2C) liquid cooling via cold plates; compatible with rear-door heat exchanger configurations |
| Coolant Type | Water or water-glycol mixture (facility-side); deionized water or dielectric fluid (IT-side) |
| Facility Water Inlet Temperature Range | 15°C to 45°C |
| IT-Side Supply Temperature Range | 20°C to 45°C (adjustable) |
| Maximum Flow Rate | Up to 600 L/min (facility-side); configurable IT-side distribution |
| Pump Configuration | Redundant variable-speed EC pump modules (N+1 standard, 2N optional) |
| Pump Redundancy | Hot-swappable pump modules with automatic failover, zero-interruption switchover |
| Working Pressure | Up to 10 bar (facility-side); up to 6 bar (IT-side distribution) |
| Leak Detection | Integrated distributed leak detection with zone isolation valves and automated shutdown triggers |
| Fluid Quality Monitoring | Inline conductivity, pH, and particulate sensing with BMS alarm integration |
| Management Protocols | Modbus TCP, BACnet/IP, SNMP v3, RESTful API |
| Local Interface | 7-inch color touchscreen HMI with trend logging and alarm history |
| Remote Monitoring | Compatible with Vertiv Environet Alert DCIM; third-party BMS integration supported |
| Power Supply | 400V / 3-phase / 50–60 Hz |
| Manifold Construction | 316L stainless steel primary manifold; high-pressure-rated flexible braided stainless distribution lines |
| Form Factor | Standalone floor-mounted unit with optional wall-mount bracket kit |
| Typical Physical Footprint | Approximately 800mm W × 1200mm D × 2000mm H (configuration-dependent) |
| Operating Ambient Temperature | 0°C to 45°C |
| Certifications | CE, UL, RoHS; IEC 62443 cybersecurity framework compliance for control interface |
| Launch Availability | Q4 2025 |
The Vertiv Liebert XDU1350 Coolant Distribution Unit is built for enterprise data-center workloads — virtualization (VMware, Proxmox, Nutanix), private cloud, database hosting, and AI/ML training. It fits standard EIA-310 server racks and supports redundant PSUs and hot-swap drives common in production environments.
Key specifications for the Vertiv Liebert XDU1350 Coolant Distribution Unit: new condition; manufacturer Vertiv; product line Liebert XDU; model XDU1350; maximum cooling capacity 1350 kW; cooling method Direct-to-chip (D2C) liquid cooling via cold plates; compatible with rear-door heat exchanger configurations; coolant type Water or water-glycol mixture (facility-side); deionized water or dielectric fluid (IT-side). Manufacturer part number XDU1350-RD. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.