Vertiv CoolPhase Liquid Cooling CDU 1.35MW

Vertiv CoolPhase Liquid Cooling CDU 1.35MW

Brand: Vertiv | Category: Accessories & Components

SKU: VERT-XDU1350 | Part #: XDU1350 | MPN: XDU1350

Contact for Pricing — Request a Quote

Request a Quote Contact Us

About the Vertiv CoolPhase Liquid Cooling CDU 1.35MW

The Vertiv CoolPhase Liquid Cooling CDU 1.35MW is a high-capacity coolant distribution unit designed to serve as the thermal backbone of next-generation AI data centers and HPC installations. Utilizing a liquid-to-liquid heat exchange architecture, the unit accepts facility-side chilled water and conditions it to precise supply temperatures required by direct-to-chip cold plates fitted to accelerators such as NVIDIA H-series and AMD Instinct GPUs. The system is engineered to handle aggregate thermal loads of up to 1.35 megawatts within a single frame, enabling data center operators to densify GPU racks far beyond what conventional air cooling permits — supporting rack densities commonly exceeding 100 kW per rack when deployed in conjunction with compatible manifold distribution systems.

At its core, the CoolPhase CDU 1.35MW incorporates variable-speed primary and secondary pump assemblies with redundant configurations, intelligent flow balancing across multiple rack-level distribution manifolds, and a built-in controls platform that communicates over SNMP, Modbus TCP, and BACnet for full integration into building management and DCIM ecosystems. The precision control system maintains coolant supply temperature within ±0.5 °C of setpoint, preventing condensation on facility infrastructure while delivering optimal thermal performance to sensitive silicon. The unit is offered in an ISO-standard 19-inch-compatible floor-standing enclosure with side-accessible service panels, reducing maintenance downtime in live production environments.

Launched in Q1 2026, the CoolPhase CDU 1.35MW targets hyperscale colocation operators, national AI research consortiums, financial services HPC clusters, and enterprise organizations deploying large-scale GPU fabrics for generative AI training and inference. Its modular internal architecture allows future capacity expansion and component replacement without full system downtime, providing a forward-looking thermal infrastructure investment aligned with the continued scaling trajectory of AI accelerator thermal design power.

Ideal for

  • Large-scale generative AI training clusters deploying hundreds of direct-liquid-cooled GPU nodes requiring centralized, high-capacity coolant distribution at megawatt scale
  • Hyperscale colocation facilities retrofitting existing data hall rows with direct-to-chip cooling to accommodate tenants running GPU-dense workloads beyond 50 kW per rack
  • National laboratory and university supercomputing centers building petascale HPC clusters where air cooling infrastructure cannot meet aggregate thermal load requirements
  • Financial services firms running real-time risk modeling and quantitative simulation workloads on GPU clusters that demand deterministic, low-latency thermal management
  • Sovereign AI infrastructure projects requiring high-reliability, redundant liquid cooling distribution with deep integration into building automation and DCIM platforms
  • Edge AI inference hubs in compact, high-density facilities where a single CDU must serve multiple GPU server rows with minimal physical footprint

Technical specifications

ManufacturerVertiv
Product LineCoolPhase Liquid Cooling CDU
ModelCoolPhase CDU 1.35MW
Maximum Cooling Capacity1,350 kW (1.35 MW)
Cooling ArchitectureLiquid-to-liquid plate-frame heat exchanger, facility water to secondary IT coolant loop
Primary (Facility) Side FluidChilled water or condenser water, compatible with standard glycol mixtures
Secondary (IT) Side FluidDeionized water or corrosion-inhibited deionized water
Secondary Coolant Supply Temperature Range15 °C – 45 °C, adjustable setpoint
Supply Temperature Control Accuracy±0.5 °C
Maximum Secondary Side Flow RateUp to 600 L/min
Pump ConfigurationDual redundant variable-speed centrifugal pumps (N+1) on both primary and secondary loops
Heat Exchanger TypeStainless steel brazed plate heat exchanger
Operating Pressure (Secondary Loop)Up to 6 bar (87 psi)
Leak DetectionIntegrated floor-level and internal leak detection sensors with alarm output
Management InterfacesSNMP v3, Modbus TCP/IP, BACnet/IP, Vertiv Liebert IntelliSlot web interface
Display & Local Controls7-inch color touchscreen HMI with real-time flow, temperature, and pressure monitoring
Input Power Supply400 V / 3-phase / 50–60 Hz
Control Power ConsumptionApproximately 8 kW (pump and controls at full load)
Physical Dimensions (H × W × D)2,000 mm × 800 mm × 1,200 mm
Weight (Operational)Approximately 850 kg
Enclosure RatingIP54
Operating Ambient Temperature Range5 °C – 45 °C
Compliance & CertificationsCE, UL/cUL, RoHS, ASHRAE A2 cooling standard compatible
LaunchQ1 2026

Available from Omnixon Global. Submit an RFQ and our team will confirm configuration and availability for your order.

Technical Specifications

BrandVertiv
CategoryAccessories & Components
SKUVERT-XDU1350
Part NumberXDU1350
ConditionNew
Product LineCoolPhase Liquid Cooling CDU
ModelCoolPhase CDU 1.35MW
Maximum Cooling Capacity1,350 kW (1.35 MW)
Cooling ArchitectureLiquid-to-liquid plate-frame heat exchanger, facility water to secondary IT coolant loop
Primary (Facility) Side FluidChilled water or condenser water, compatible with standard glycol mixtures
Secondary (IT) Side FluidDeionized water or corrosion-inhibited deionized water
Secondary Coolant Supply Temperature Range15 °C – 45 °C, adjustable setpoint
Supply Temperature Control Accuracy±0.5 °C
Maximum Secondary Side Flow RateUp to 600 L/min
Pump ConfigurationDual redundant variable-speed centrifugal pumps (N+1) on both primary and secondary loops
Heat Exchanger TypeStainless steel brazed plate heat exchanger
Operating Pressure (Secondary Loop)Up to 6 bar (87 psi)
Leak DetectionIntegrated floor-level and internal leak detection sensors with alarm output
Management InterfacesSNMP v3, Modbus TCP/IP, BACnet/IP, Vertiv Liebert IntelliSlot web interface
Display & Local Controls7-inch color touchscreen HMI with real-time flow, temperature, and pressure monitoring
Input Power Supply400 V / 3-phase / 50–60 Hz
Control Power ConsumptionApproximately 8 kW (pump and controls at full load)
Physical Dimensions (H × W × D)2,000 mm × 800 mm × 1,200 mm
Weight (Operational)Approximately 850 kg
Enclosure RatingIP54
Operating Ambient Temperature Range5 °C – 45 °C
Compliance & CertificationsCE, UL/cUL, RoHS, ASHRAE A2 cooling standard compatible
LaunchQ1 2026

Frequently Asked Questions about Vertiv CoolPhase Liquid Cooling CDU 1.35MW

What does the Vertiv CoolPhase Liquid Cooling CDU 1.35MW do?

The Vertiv CoolPhase Liquid Cooling CDU 1.35MW is enterprise IT hardware deployed in production data centers, server rooms, and edge sites across the GCC and EMEA region.

What are the headline specs of the Vertiv CoolPhase Liquid Cooling CDU 1.35MW?

Key specifications for the Vertiv CoolPhase Liquid Cooling CDU 1.35MW: new condition; manufacturer Vertiv; product line CoolPhase Liquid Cooling CDU; model CoolPhase CDU 1.35MW; maximum cooling capacity 1,350 kW (1.35 MW); cooling architecture Liquid-to-liquid plate-frame heat exchanger, facility water to secondary IT coolant loop; primary (facility) side fluid Chilled water or condenser water, compatible with standard glycol mixtures. Manufacturer part number XDU1350. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.