Brand: Huawei | Category: UPS & Power Protection
SKU: UPS5000-E-400K | Part #: UPS5000-E-400K | MPN: UPS5000-E-400K
Contact for Pricing — Request a Quote
The Huawei UPS5000-E-400K Modular UPS delivers 400 kVA and 400 kW of continuous output power, engineered as an online double-conversion system that maintains uninterrupted power delivery to mission-critical enterprise infrastructure. This modular architecture supports N+X redundancy, enabling IT procurement teams and infrastructure managers to scale protection without replacing core hardware, while achieving up to 96% efficiency in normal operation and up to 99% in ECO mode.
Built to Huawei's proven standards compliance—IEC 62040-1, IEC 62040-2, and IEC 62040-3—the UPS5000-E-400K accepts 3-phase input voltage of 380/400/415 V AC across a wide input range of 138 V to 485 V AC, accommodating diverse regional power conditions across the MENA region and beyond. The unit synchronizes output frequency to the input (50 Hz or 60 Hz configurable) with zero millisecond transfer time to bypass mode, ensuring voltage regulation within ±1% static tolerance. Communication intelligence includes SNMP, RS485, and dry contact interfaces for seamless integration into centralized monitoring ecosystems, while operating reliably between 0 °C to 40 °C in humidity environments from 5% to 95% non-condensing.
For detailed specifications on the Huawei UPS5000-E-400K (part number UPS5000-E-400K) and to request a formal quotation, contact the Omnixon Global technical team today.
| Brand | Huawei |
| Category | UPS & Power Protection |
| SKU | UPS5000-E-400K |
| Part Number | UPS5000-E-400K |
| Condition | New |
| Manufacturer Part Number | UPS5000-E-400K |
| Topology | Online Double-Conversion (VFI) |
| Rated Capacity | 400 kVA / 400 kW |
| Power Factor (Output) | 1.0 |
| Efficiency (Normal Mode) | Up to 96% |
| Efficiency (ECO Mode) | Up to 99% |
| Input Voltage | 3-phase, 380/400/415 V AC (configurable) |
| Input Voltage Range | 138 V – 485 V AC (wide input) |
| Input Power Factor | ≥ 0.99 at full load |
| Input Frequency Range | 45 Hz – 65 Hz |
| Output Voltage | 380/400/415 V AC, 3-phase |
| Output Voltage Regulation (Static) | ± 1% |
| Output Frequency | 50 Hz or 60 Hz (synchronized to input or free-running) |
| Transfer Time (Online to Bypass) | 0 ms |
| Architecture | Hot-swap modular; supports N+X redundancy |
| Communication Interfaces | SNMP, RS485, dry contact (configurable) |
| Operating Temperature | 0 °C to 40 °C |
| Relative Humidity (Operating) | 5% – 95% non-condensing |
| Standards Compliance | IEC 62040-1, IEC 62040-2, IEC 62040-3 |
| Battery Management | Intelligent battery management with state-of-health monitoring and temperature-compensated charging |
Runtime is load-dependent. Most enterprise UPS at 50% load deliver 8-12 minutes battery on standard internal batteries. Add external battery packs (XL / RBC modules) to extend to 30-60 minutes if you need ride-through past short utility blips.
Yes — we ship the SNMP / Network Management Card (NMC) alongside the UPS, plus shutdown agents that integrate with VMware PowerChute, Veeam, NetApp ONTAP, and standard SNMP traps for orchestration platforms.
For Dubai and the wider UAE we offer installation, commissioning, and battery recycling per municipality regulations. For broader GCC we partner with local certified electricians and recyclers — included as an option in the quote.
Stocked tier (under 10 kVA): 5-7 business days. 10-20 kVA: 2-4 weeks typically. 20+ kVA modular / parallel systems: 6-10 weeks vendor-side, plus on-site commissioning scheduling. Real numbers quoted with every order.