Brand: HPE | Category: UPS & Power Protection
SKU: HP-Q8B70A | Part #: Q8B70A | MPN: Q8B70A
Contact for Pricing — Request a Quote
The HPE R7000 UPS 15kVA is a rack-mounted, three-phase online double-conversion uninterruptible power supply engineered for enterprise data centers and mission-critical infrastructure environments. Operating on a true double-conversion topology, it provides complete galvanic isolation between input and output, eliminating voltage fluctuations, harmonic distortion, and frequency instability from reaching connected loads. The unit supports a wide input voltage range and power factor correction to minimize stress on upstream electrical infrastructure, making it suitable for deployment in facilities with variable or unreliable grid conditions. With a compact 12U rack form factor, the R7000 optimizes floor space utilization while delivering the power density demanded by high-density compute and storage deployments launched into production in 2025-Q1.
A defining capability of the HPE R7000 UPS 15kVA is its 98% efficiency rating achieved in eco-mode operation, which significantly reduces heat dissipation and facility cooling overhead compared to conventional UPS designs. When grid conditions are stable, eco-mode passes power through a static bypass with minimal conversion loss, automatically reverting to full double-conversion protection within milliseconds upon detecting anomalies. This intelligent efficiency management directly translates to measurable reductions in power usage effectiveness (PUE) metrics at the data center level. The optional Lithium-Ion battery configuration provides substantial advantages over traditional VRLA technology, including reduced weight, longer cycle life exceeding 10 years, faster recharge times, and a wider operating temperature range that relaxes battery room environmental requirements.
The HPE R7000 UPS 15kVA integrates natively with Schneider Electric EcoStruxure architecture, enabling centralized power monitoring, predictive battery health analytics, and automated load management through a unified management plane. The embedded network management card exposes SNMP, Modbus TCP, and REST API interfaces, allowing integration with HPE OneView, OpenManage, and third-party DCIM platforms. Scalable runtime extension is supported via external battery module cabinets, and the unit features hot-swappable battery modules to facilitate maintenance without planned downtime windows. Redundant N+1 parallel operation supports up to four units for higher availability configurations in Tier III and Tier IV data center designs.
| Manufacturer | HP (HPE) |
| Model | HPE R7000 UPS 15kVA |
| UPS Topology | Online Double-Conversion (VFI per IEC 62040-3) |
| Power Rating | 15 kVA / 15 kW |
| Output Power Factor | 1.0 (unity) |
| Input Phase Configuration | Three-phase, 3-wire + neutral + ground |
| Input Voltage Range | 380/400/415 V AC (three-phase), ±15% without battery |
| Input Frequency Range | 45–65 Hz (auto-sensing) |
| Input Power Factor Correction | ≥0.99 at full load |
| Input THDi | <3% at full load |
| Output Voltage | 380/400/415 V AC three-phase (selectable) |
| Output Frequency | 50/60 Hz ± 0.1% (synchronized), ±0.5 Hz free-running |
| Output Voltage Regulation | ±1% (double-conversion mode) |
| Overload Capacity | 125% for 10 minutes; 150% for 1 minute |
| Transfer Time (Eco to Double-Conversion) | <2 ms |
| Peak Efficiency (Double-Conversion) | 96.5% |
| Peak Efficiency (Eco-Mode) | 98% |
| Battery Technology Options | VRLA (standard) / Lithium-Ion (optional) |
| Battery Configuration | Hot-swappable internal modules; external battery module (EBM) expansion supported |
| Li-Ion Battery Service Life | >10 years (vs. 3–5 years VRLA) |
| Battery Recharge Time | <2 hours to 90% capacity (Li-Ion configuration) |
| Typical Runtime at Full Load | ~8 minutes internal battery (VRLA); extended via EBM |
| Communication Interfaces | SNMP v1/v2c/v3, Modbus TCP, REST API, USB, RS-232 |
| Management Integration | EcoStruxure IT, HPE OneView, OpenManage, standard DCIM via SNMP/Modbus |
| Display | Color LCD touchscreen with real-time load, battery status, and event logs |
| Form Factor | Rack-mount, 12U |
| Audible Noise | <55 dBA at 1 meter |
| Operating Temperature | 0°C to 40°C (VRLA); -10°C to 50°C (Li-Ion) |
| Relative Humidity | 5%–95% non-condensing |
| Certifications | IEC 62040-1, IEC 62040-2 (Class C2), CE, UL 1778, RoHS |
| Parallel Redundancy | Up to 4 units in N+1 parallel configuration |
Available from Omnixon Global. Submit an RFQ and our team will confirm configuration and availability for your order.
| Brand | HPE |
| Category | UPS & Power Protection |
| SKU | HP-Q8B70A |
| Part Number | Q8B70A |
| Condition | New |
| Model | HPE R7000 UPS 15kVA |
| UPS Topology | Online Double-Conversion (VFI per IEC 62040-3) |
| Power Rating | 15 kVA / 15 kW |
| Output Power Factor | 1.0 (unity) |
| Input Phase Configuration | Three-phase, 3-wire + neutral + ground |
| Input Voltage Range | 380/400/415 V AC (three-phase), ±15% without battery |
| Input Frequency Range | 45–65 Hz (auto-sensing) |
| Input Power Factor Correction | ≥0.99 at full load |
| Input THDi | <3% at full load |
| Output Voltage | 380/400/415 V AC three-phase (selectable) |
| Output Frequency | 50/60 Hz ± 0.1% (synchronized), ±0.5 Hz free-running |
| Output Voltage Regulation | ±1% (double-conversion mode) |
| Overload Capacity | 125% for 10 minutes; 150% for 1 minute |
| Transfer Time (Eco to Double-Conversion) | <2 ms |
| Peak Efficiency (Double-Conversion) | 96.5% |
| Peak Efficiency (Eco-Mode) | 98% |
| Battery Technology Options | VRLA (standard) / Lithium-Ion (optional) |
| Battery Configuration | Hot-swappable internal modules; external battery module (EBM) expansion supported |
| Li-Ion Battery Service Life | >10 years (vs. 3–5 years VRLA) |
| Battery Recharge Time | <2 hours to 90% capacity (Li-Ion configuration) |
| Typical Runtime at Full Load | ~8 minutes internal battery (VRLA); extended via EBM |
| Communication Interfaces | SNMP v1/v2c/v3, Modbus TCP, REST API, USB, RS-232 |
| Management Integration | EcoStruxure IT, HPE OneView, OpenManage, standard DCIM via SNMP/Modbus |
| Display | Color LCD touchscreen with real-time load, battery status, and event logs |
| Form Factor | Rack-mount, 12U |
| Audible Noise | <55 dBA at 1 meter |
| Operating Temperature | 0°C to 40°C (VRLA); -10°C to 50°C (Li-Ion) |
| Relative Humidity | 5%–95% non-condensing |
| Certifications | IEC 62040-1, IEC 62040-2 (Class C2), CE, UL 1778, RoHS |
| Parallel Redundancy | Up to 4 units in N+1 parallel configuration |
The HPE R7000 UPS 15kVA delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
Key specifications for the HPE R7000 UPS 15kVA: new condition; manufacturer HP (HPE); model HPE R7000 UPS 15kVA; ups topology Online Double-Conversion (VFI per IEC 62040-3); power rating 15 kVA / 15 kW; output power factor 1.0 (unity); input phase configuration Three-phase, 3-wire + neutral + ground. Manufacturer part number Q8B70A. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.