Brand: Eaton | Category: UPS & Power Protection
SKU: 9PX6KSP | Part #: 9PX6KSP | MPN: 9PX6KSP
Contact for Pricing — Request a Quote
The Eaton 9PX 6000VA 6kVA Tower UPS (part number 9PX6KSP) accepts input voltage from 200–240V AC in both single-phase and three-phase configurations, with output voltage similarly rated at 200–240V AC and configurable to match your facility requirements. This tower-form factor unit delivers 6000VA of continuous power protection using Eaton's proven double-conversion online topology, ensuring zero-millisecond transfer time during mains failures—meaning connected equipment experiences no switchover delay or momentary power loss.
Network engineers, data center managers, and IT procurement teams choose the 9PX6KSP for mission-critical applications where uninterrupted uptime is non-negotiable. The unit communicates via USB, RS-232, and SNMP/NMC card connectivity, enabling seamless integration into existing monitoring and management infrastructure. Operating silently at less than 65 dB under typical loads and maintaining a 0.9 power factor, the 9PX operates reliably across ambient temperatures from 0–40°C, making it suitable for standard server rooms and controlled environments alike.
Whether you're protecting a growing virtualization cluster, securing branch office infrastructure, or safeguarding sensitive data processing applications, the Eaton 9PX 6000VA delivers enterprise-grade reliability at a scalable capacity.
| Brand | Eaton |
| Category | UPS & Power Protection |
| SKU | 9PX6KSP |
| Part Number | 9PX6KSP |
| Condition | New |
| Capacity | 6000VA |
| Form Factor | Tower |
| Communication | USB, RS-232, SNMP / NMC card |
| Topology | Double-Conversion Online |
| Manufacturer Part Number | 9PX6KSP |
| Input Voltage | 200–240V AC, single-phase or three-phase |
| Output Voltage | 200–240V AC (configurable) |
| Communication Ports | USB, RS-232, SNMP / NMC card |
| Transfer Time | 0 ms (no switchover on-line mode) |
| Operating Temperature | 0–40°C |
| Noise Level | < 65 dB (typical) |
| Power Factor | 0.9 |
Runtime is load-dependent. Most enterprise UPS at 50% load deliver 8-12 minutes battery on standard internal batteries. Add external battery packs (XL / RBC modules) to extend to 30-60 minutes if you need ride-through past short utility blips.
Yes — we ship the SNMP / Network Management Card (NMC) alongside the UPS, plus shutdown agents that integrate with VMware PowerChute, Veeam, NetApp ONTAP, and standard SNMP traps for orchestration platforms.