Brand: Eaton | Category: UPS & Power Protection
SKU: EATO-93PM20 | Part #: 93PM-20 | MPN: 93PM-20
Contact for Pricing — Request a Quote
The Eaton 93PM G2 UPS at 20kW represents the second generation of Eaton's proven 93PM modular architecture, engineered specifically for medium data centers, edge computing facilities, and distributed enterprise IT environments. Built on a hot-swappable power module platform, the system allows organizations to start at a base capacity and scale incrementally without system downtime, reducing stranded capital while aligning power infrastructure with actual IT growth. The double-conversion online topology ensures complete galvanic isolation between utility input and critical load, delivering clean, regulated power regardless of input disturbances including voltage sags, surges, frequency variations, and total utility failures.
At the heart of the 93PM G2 is Eaton's advanced DSP-controlled IGBT rectifier and inverter stage, which achieves up to 97% efficiency in double-conversion mode and exceeds 99% in Eaton's proprietary Energy Saver System (ESS) mode — a high-efficiency operating mode that activates bypass while continuously monitoring power quality and seamlessly transitions to full conversion within milliseconds when anomalies are detected. This dual-mode efficiency capability significantly reduces annual operational energy expenditure in facilities where power costs are a primary concern. The unity input power factor and low total harmonic distortion (THDi < 3%) eliminate the need for upstream harmonic filters, simplifying upstream electrical infrastructure.
The 93PM G2 is designed with serviceability and operational continuity as primary engineering mandates. All power modules, bypass modules, and control electronics are front-accessible, enabling full maintenance activities without rear-of-cabinet access — a critical advantage in high-density row-based data center layouts. Integration with Eaton's Intelligent Power Manager (IPM) software and compatibility with SNMP, Modbus, and BACnet protocols ensures seamless embedding into existing data center infrastructure management (DCIM) and building management systems (BMS), providing granular telemetry on load, efficiency, battery health, and environmental parameters.
| Manufacturer | Eaton |
| Model | 93PM G2 20kW |
| Topology | Double-conversion online (VFI SS 111 per IEC 62040-3) |
| Power Rating | 20 kW / 20 kVA |
| Scalability | Hot-swappable power modules; scalable in 5kW increments up to frame maximum |
| Input Voltage | 380/400/415V three-phase (configurable) |
| Input Voltage Range | 160V – 470V (phase-to-phase) without battery discharge |
| Input Frequency | 45 – 65 Hz (auto-sensing) |
| Input Power Factor | >0.99 at full load |
| Input THDi | < 3% at full load |
| Output Voltage | 380/400/415V three-phase, selectable |
| Output Frequency | 50 Hz or 60 Hz ± 0.1% (inverter mode) |
| Output Voltage Distortion (THDu) | < 2% with linear load; < 5% with non-linear load |
| Efficiency (Double-Conversion) | Up to 97% at full load |
| Efficiency (Energy Saver System Mode) | Up to 99% |
| Transfer Time (ESS to Double-Conversion) | < 10 ms typical |
| Overload Capacity | 110% for 60 minutes; 125% for 10 minutes; 150% for 1 minute |
| Battery Compatibility | Internal VRLA or external battery cabinet (Eaton EBC series); Lithium-ion battery option supported |
| Communication Interfaces | USB, RS-232, dry contacts; optional SNMP/HTTP card, Modbus RTU/TCP, BACnet |
| Management Software | Compatible with Eaton Intelligent Power Manager (IPM) and Brightlayer Data Centers suite |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
| Relative Humidity | 5% to 95% non-condensing |
| Audible Noise | < 55 dBA at 1 meter |
| Form Factor | Tower / rack-convertible modular frame |
| Dimensions (H x W x D) | Approximately 1200 mm x 600 mm x 800 mm (frame; varies by configuration) |
| Certifications | IEC 62040-1 (safety), IEC 62040-2 (EMC Class C2), IEC 62040-3 (performance VFI), CE marking |
Available from Omnixon Global. Submit an RFQ and our team will confirm configuration and availability for your order.
| Brand | Eaton |
| Category | UPS & Power Protection |
| SKU | EATO-93PM20 |
| Part Number | 93PM-20 |
| Condition | New |
| Model | 93PM G2 20kW |
| Topology | Double-conversion online (VFI SS 111 per IEC 62040-3) |
| Power Rating | 20 kW / 20 kVA |
| Scalability | Hot-swappable power modules; scalable in 5kW increments up to frame maximum |
| Input Voltage | 380/400/415V three-phase (configurable) |
| Input Voltage Range | 160V – 470V (phase-to-phase) without battery discharge |
| Input Frequency | 45 – 65 Hz (auto-sensing) |
| Input Power Factor | >0.99 at full load |
| Input THDi | < 3% at full load |
| Output Voltage | 380/400/415V three-phase, selectable |
| Output Frequency | 50 Hz or 60 Hz ± 0.1% (inverter mode) |
| Output Voltage Distortion (THDu) | < 2% with linear load; < 5% with non-linear load |
| Efficiency (Double-Conversion) | Up to 97% at full load |
| Efficiency (Energy Saver System Mode) | Up to 99% |
| Transfer Time (ESS to Double-Conversion) | < 10 ms typical |
| Overload Capacity | 110% for 60 minutes; 125% for 10 minutes; 150% for 1 minute |
| Battery Compatibility | Internal VRLA or external battery cabinet (Eaton EBC series); Lithium-ion battery option supported |
| Communication Interfaces | USB, RS-232, dry contacts; optional SNMP/HTTP card, Modbus RTU/TCP, BACnet |
| Management Software | Compatible with Eaton Intelligent Power Manager (IPM) and Brightlayer Data Centers suite |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
| Relative Humidity | 5% to 95% non-condensing |
| Audible Noise | < 55 dBA at 1 meter |
| Form Factor | Tower / rack-convertible modular frame |
| Dimensions (H x W x D) | Approximately 1200 mm x 600 mm x 800 mm (frame; varies by configuration) |
| Certifications | IEC 62040-1 (safety), IEC 62040-2 (EMC Class C2), IEC 62040-3 (performance VFI), CE marking |
The Eaton 93PM G2 UPS 20kW delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
The Eaton 93PM G2 UPS 20kW delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
Key specifications for the Eaton 93PM G2 UPS 20kW: new condition; manufacturer Eaton; model 93PM G2 20kW; topology Double-conversion online (VFI SS 111 per IEC 62040-3); power rating 20 kW / 20 kVA; scalability Hot-swappable power modules; scalable in 5kW increments up to frame maximum; input voltage 380/400/415V three-phase (configurable). Manufacturer part number 93PM-20. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.
Key specifications for the Eaton 93PM G2 UPS 20kW: new condition; manufacturer Eaton; model 93PM G2 20kW; topology Double-conversion online (VFI SS 111 per IEC 62040-3); power rating 20 kW / 20 kVA; scalability Hot-swappable power modules; scalable in 5kW increments up to frame maximum; input voltage 380/400/415V three-phase (configurable). Manufacturer part number 93PM-20. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.