Brand: APC | Category: Rack PDUs
SKU: AP7555A | Part #: AP7555A | MPN: AP7555A
Contact for Pricing — Request a Quote
The APC AP7555A is a Basic Vertical PDU for distributing power to equipment in a server or network rack. It mounts vertically in a 0U position and has a black finish. Input is through an IEC 309 32A 3P+N+PE connection on a 1.83 m cable, at a nominal input voltage of 400 V and an AC input frequency of 47/63 Hz.
The unit provides 9 AC outlets: six IEC 320 C19 and three IEC 320 C13, at a nominal output voltage of 230 V. Maximum power is 22000 W, load capacity is 22080 VA, and the maximum input current is 32 A per phase.
As a basic PDU, it suits three-phase rack deployments that need high-capacity outlet distribution. Rated operating temperature is -5 to 45 °C and storage temperature is -25 to 65 °C, with 5 to 95% relative humidity for both operation and storage.
Send the part number through our RFQ form and our team will reply within 48 hours.
| Brand | APC |
| Category | Rack PDUs |
| SKU | AP7555A |
| Part Number | AP7555A |
| Condition | New |
| Output connections | - (3) IEC 320 C13 - (6) IEC 320 C19 |
| Input connection type | IEC 309 32A 3P+N+PE |
| AC outlet types | C13 coupler, C19 coupler |
| AC outlets quantity | 9 AC outlet(s) |
| Cable length | 1.83 m |
| Maximum power | 22000 W |
| Maximum total current draw per phase | 32 A |
| Maximum input current per phase | 32 A |
| Load capacity | 22080 VA |
| Nominal output voltage | 230 V |
| AC input frequency | 47/63 Hz |
| Nominal input voltage | 400 V |
| Product colour | Black |
| Mounting | Vertical |
| Rack capacity | 0U |
| PDU types | Basic |
| Operating relative humidity (H-H) | 5 - 95% |
| Storage relative humidity (H-H) | 5 - 95% |
| Storage temperature (T-T) | -25 - 65 °C |
| Operating temperature (T-T) | -5 - 45 °C |
| Weight | 4.75 kg |
| Height | 927 mm |
| Depth | 88 mm |
| Width | 55 mm |
The APC Basic Vertical PDU, 400V 16A, 22KW, C19(6), C13(3), IEC-309 delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
Key specifications for the APC Basic Vertical PDU, 400V 16A, 22KW, C19(6), C13(3), IEC-309: new condition; output connections - (3) IEC 320 C13 - (6) IEC 320 C19; input connection type IEC 309 32A 3P+N+PE; ac outlet types C13 coupler, C19 coupler; ac outlets quantity 9 AC outlet(s); cable length 1.83 m; maximum power 22000 W. Manufacturer part number AP7555A. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.