Brand: APC | Category: Rack PDUs
SKU: AP7586 | Part #: AP7586 | MPN: AP7586
Contact for Pricing — Request a Quote
The APC AP7586 is a Basic Rack PDU Extender in a 2U horizontal-mount format, used to distribute power to equipment in a rack. It provides four IEC 309 outlets and accepts a hard-wired 3-wire input, with a cable length of 8.53 m.
The unit operates at a nominal input and output voltage of 230 V, with a maximum input current and maximum total current draw of 32 A per phase. Maximum power is 7680 W and load capacity is 7680 VA. The housing is black. Rated operating conditions are 0 to 45 °C and 0 to 45% relative humidity. Storage conditions are -25 to 65 °C and 0 to 95% relative humidity.
As a basic power distribution unit, it suits server rooms and data centre racks where additional high-current outlets are needed for rack-mounted IT equipment.
Send the part number through our RFQ form and our team will reply within 48 hours.
| Brand | APC |
| Category | Rack PDUs |
| SKU | AP7586 |
| Part Number | AP7586 |
| Condition | New |
| Output connections | (4) IEC 309 |
| Input connection type | Hard Wire 3-wire |
| I/O ports | Hard Wire 3-wire (4) IEC 309 |
| AC outlets quantity | 4 AC outlet(s) |
| Cable length | 8.53 m |
| Maximum power | 7680 W |
| Maximum total current draw per phase | 32 A |
| Maximum input current per phase | 32 A |
| Load capacity | 7680 VA |
| Output voltage | 230 V |
| Nominal output voltage | 230 V |
| Nominal input voltage | 230 V |
| Product colour | Black |
| Mounting | Horizontal |
| Rack capacity | 2U |
| PDU types | Basic |
| Operating relative humidity (H-H) | 0 - 45% |
| Storage relative humidity (H-H) | 0 - 95% |
| Storage temperature (T-T) | -25 - 65 °C |
| Operating temperature (T-T) | 0 - 45 °C |
| Weight | 4.09 kg |
| Height | 89 mm |
| Depth | 89 mm |
| Width | 437 mm |
The APC Rack PDU Extender, BASIC, 2U, 32A, 230V, (4) IEC 309-32 (AP7586) delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
Key specifications for the APC Rack PDU Extender, BASIC, 2U, 32A, 230V, (4) IEC 309-32 (AP7586): new condition; output connections (4) IEC 309; input connection type Hard Wire 3-wire; i/o ports Hard Wire 3-wire (4) IEC 309; ac outlets quantity 4 AC outlet(s); cable length 8.53 m; maximum power 7680 W. Manufacturer part number AP7586. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.