Netshelter Rack PDU Advanced, Switched, 3PH, 30A, 48 Outlet (APDU10350SW)

Netshelter Rack PDU Advanced, Switched, 3PH, 30A, 48 Outlet (APDU10350SW)

Brand: APC | Category: Rack PDUs

SKU: APDU10350SW | Part #: APDU10350SW | MPN: APDU10350SW

Contact for Pricing — Request a Quote

Request a Quote Contact Us

About the Netshelter Rack PDU Advanced, Switched, 3PH, 30A, 48 Outlet (APDU10350SW)

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

Technical Specifications

BrandAPC
CategoryRack PDUs
SKUAPDU10350SW
Part NumberAPDU10350SW
ConditionNew
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Power plugIEC 60309
AC outlets quantity24 AC outlet(s)
Daisy chainYes
Maximum total current draw per phase24 A
Maximum input current per phase30 A
Load capacity17300 VA
Nominal output voltage240 V
Maximum current24 A
AC input frequency50 - 60 Hz
Nominal input voltage240V
On/off switchNo
DisplayLCD
Product colourBlack
MountingVertical
Rack capacity0U
TypeThree-phase
PDU typesSwitched
Non-operating altitude0 - 15240 m
Operating altitude0 - 3048 m
Operating relative humidity (H-H)5 - 95%
Storage relative humidity (H-H)5 - 95%
Storage temperature (T-T)-25 - 65 °C
Operating temperature (T-T)-5 - 60 °C
Weight9.6 kg
Height1780 mm
Depth75 mm
Width56 mm
CertificationCE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1

Frequently Asked Questions about Netshelter Rack PDU Advanced, Switched, 3PH, 30A, 48 Outlet (APDU10350SW)

What does the Netshelter Rack PDU Advanced, Switched, 3PH, 30A, 48 Outlet (APDU10350SW) do?

The Netshelter Rack PDU Advanced, Switched, 3PH, 30A, 48 Outlet (APDU10350SW) delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.

What are the headline specs of the Netshelter Rack PDU Advanced, Switched, 3PH, 30A, 48 Outlet (APDU10350SW)?

Key specifications for the Netshelter Rack PDU Advanced, Switched, 3PH, 30A, 48 Outlet (APDU10350SW): new condition; ac outlet types C13 coupler, C15 coupler, C19 coupler, C21 coupler; power plug IEC 60309; ac outlets quantity 24 AC outlet(s); daisy chain Yes; maximum total current draw per phase 24 A; maximum input current per phase 30 A. Manufacturer part number APDU10350SW. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.