Netshelter Rack PDU Advanced, METERED, 3PH, 415V, 60A, 42 Outlet (APDU10450ME)

Netshelter Rack PDU Advanced, METERED, 3PH, 415V, 60A, 42 Outlet (APDU10450ME)

Brand: APC | Category: Rack PDUs

SKU: APDU10450ME | Part #: APDU10450ME | MPN: APDU10450ME

Contact for Pricing — Request a Quote

Request a Quote Contact Us

About the Netshelter Rack PDU Advanced, METERED, 3PH, 415V, 60A, 42 Outlet (APDU10450ME)

The APC NetShelter Rack PDU Advanced (part number APDU10450ME) is a rack power distribution unit for vertical, 0U mounting in equipment racks. It takes a nominal 415 V input through an IEC 60309 plug and delivers a nominal 240 V output. Its load capacity is 34600 VA at an AC input frequency of 50 to 60 Hz.

Maximum input current is 60 A per phase, with a maximum total current draw of 48 A per phase. Outlets are a mix of C13, C15, C19 and C21 couplers, so equipment with different power cord types can share one unit. The PDU has an LCD display and supports daisy chaining. It has no on/off switch and comes in a black finish.

Units of this type are used in data centres, server rooms and network racks to distribute power to servers, storage and networking equipment from a single high-capacity feed.

Send the part number through our RFQ form and our team will reply within 48 hours.

Technical Specifications

BrandAPC
CategoryRack PDUs
SKUAPDU10450ME
Part NumberAPDU10450ME
ConditionNew
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Power plugIEC 60309
AC outlets quantity48 AC outlet(s)
Daisy chainYes
Maximum total current draw per phase48 A
Maximum input current per phase60 A
Load capacity34600 VA
Output voltage240 V
Nominal output voltage240 V
Maximum current60 A
AC input frequency50 - 60 Hz
Nominal input voltage415 V
On/off switchNo
DisplayLCD
Product colourBlack
MountingVertical
Rack capacity0U
TypeSingle-phase
PDU typesSwitched
Non-operating altitude0 - 15240 m
Operating altitude0 - 3048 m
Operating relative humidity (H-H)5 - 95%
Storage relative humidity (H-H)5 - 95%
Storage temperature (T-T)-25 - 65 °C
Operating temperature (T-T)-5 - 60 °C
Weight11.7 kg
Height1826 mm
Depth75 mm
Width56 mm
CertificationCSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1

Frequently Asked Questions about Netshelter Rack PDU Advanced, METERED, 3PH, 415V, 60A, 42 Outlet (APDU10450ME)

What does the Netshelter Rack PDU Advanced, METERED, 3PH, 415V, 60A, 42 Outlet (APDU10450ME) do?

The Netshelter Rack PDU Advanced, METERED, 3PH, 415V, 60A, 42 Outlet (APDU10450ME) delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.

What are the headline specs of the Netshelter Rack PDU Advanced, METERED, 3PH, 415V, 60A, 42 Outlet (APDU10450ME)?

Key specifications for the Netshelter Rack PDU Advanced, METERED, 3PH, 415V, 60A, 42 Outlet (APDU10450ME): new condition; ac outlet types C13 coupler, C15 coupler, C19 coupler, C21 coupler; power plug IEC 60309; ac outlets quantity 48 AC outlet(s); daisy chain Yes; maximum total current draw per phase 48 A; maximum input current per phase 60 A. Manufacturer part number APDU10450ME. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.