(APDU10450ME) NETSHELTER RACK PDU ADVANCED, METERED,3PH, 415V, 60A, 42 OUTLET

(APDU10450ME) NETSHELTER RACK PDU ADVANCED, METERED,3PH, 415V, 60A, 42 OUTLET

Brand: APC | Category: Server Racks & Enclosures

SKU: APDU10450ME | Part #: APDU10450ME | MPN: APDU10450ME

Contact for Pricing — Request a Quote

Request a Quote Contact Us

About the (APDU10450ME) NETSHELTER RACK PDU ADVANCED, METERED,3PH, 415V, 60A, 42 OUTLET

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

Technical Specifications

BrandAPC
CategoryServer Racks & Enclosures
SKUAPDU10450ME
Part NumberAPDU10450ME
ConditionNew
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Power plugIEC 60309
AC outlets quantity48 AC outlet(s)
Daisy chainYes
Maximum total current draw per phase48 A
Maximum input current per phase60 A
Load capacity34600 VA
Output voltage240 V
Nominal output voltage240 V
Maximum current60 A
AC input frequency50 - 60 Hz
Nominal input voltage415 V
On/off switchNo
DisplayLCD
Product colourBlack
MountingVertical
Rack capacity0U
TypeSingle-phase
PDU typesSwitched
Non-operating altitude0 - 15240 m
Operating altitude0 - 3048 m
Operating relative humidity (H-H)5 - 95%
Storage relative humidity (H-H)5 - 95%
Storage temperature (T-T)-25 - 65 °C
Operating temperature (T-T)-5 - 60 °C
Weight11.7 kg
Height1826 mm
Depth75 mm
Width56 mm
CertificationCSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1