About the Acer Altos UPS 1500VA Rack/Tower UPS

The Acer Altos UPS 1500VA is a true online double-conversion uninterruptible power supply engineered for mission-critical deployments requiring continuous power conditioning and instantaneous failover protection. Operating in dual-conversion mode, the unit converts incoming AC to DC, then reconverts to clean AC output, isolating connected equipment from utility voltage fluctuations, frequency drift, and transient disturbances. This architecture ensures zero-transfer-time switching during mains failure, eliminating any perceptible power gap that could disrupt sensitive medical imaging systems, hospital IT infrastructure, or enterprise server rooms.

Designed for flexible deployment, the Altos 1500VA supports both rack-mount and tower configurations, adapting to constrained data center layouts and modular clinic fit-outs. The unit targets organizations where power quality directly impacts patient safety, diagnostic accuracy, and business continuity—particularly healthcare facilities performing real-time imaging and clinical informatics workflows. Since its Q4 2023 launch, the Altos 1500VA has achieved steady market adoption across hospital capital equipment programs and clinic facility upgrades requiring compact, conditioned backup power without sacrificing runtime or load capacity.

The system integrates intelligent battery management, scalable runtime options via external battery modules, and comprehensive monitoring interfaces enabling remote status visibility and predictive maintenance alerts. Enterprise administrators benefit from SNMP-based network integration, allowing the UPS to signal connected infrastructure of power events and orchestrate graceful shutdown sequences across virtualized and physical workloads.

Ideal for

  • Hospital IT rooms: Protecting clinical information systems, electronic health record servers, and network infrastructure during mains interruptions and brownouts
  • Medical imaging suites: Supplying uninterrupted, conditioned power to CT, MRI, ultrasound, and X-ray systems requiring stable voltage and frequency for diagnostic image quality and equipment longevity
  • Diagnostic laboratory facilities: Ensuring continuous operation of automated analyzers, PACS servers, and result-management systems in blood bank and pathology departments
  • Clinic administrative centers: Backing up reception systems, scheduling databases, and billing infrastructure during extended utility outages affecting multi-tenant medical office buildings
  • Enterprise server rooms: Protecting virtualization hosts, storage arrays, and network switches in corporate data centers against utility instability and supporting orderly shutdown during extended outages
  • Modular field deployments: Providing portable backup power for mobile ultrasound units, telemedicine carts, and temporary diagnostic facilities in remote or disaster-response healthcare settings

Technical specifications

ManufacturerAcer
Product LineAltos UPS
Model1500VA
UPS TypeDual-conversion online (VFI SS 111)
TopologyTrue online with rectifier, inverter, and static bypass
Input Voltage Range176–264 VAC (adjustable tolerance window)
Input Frequency50/60 Hz ±5 Hz (auto-sensing)
Output Voltage220/230/240 VAC (selectable) ±2%
Output Frequency50/60 Hz synchronized to inverter ±0.5 Hz
VA Rating1500 VA
Power Output1050 W at 0.7 power factor; up to 1500 W at 1.0 pf (resistive load)
Efficiency (Online Mode)≥92% (typical at 50% load)
Transfer Time (Mains to Battery)<1 ms (zero in online mode)
Battery TypeSealed lead-acid (VRLA), user-replaceable
Backup Runtime at Full Load8–12 minutes (dependent on battery configuration)
Runtime at 50% Load15–20 minutes
External Battery ModulesSupported; extends runtime to 45+ minutes at rated load
Deployment OptionsRack-mount (2U) or tower/pedestal configuration
CoolingForced-air convection with thermal management
Input Connectors1× IEC 60320 C20 (three-phase optional)
Output Connectors4× IEC 60320 C13 + 1× IEC 60320 C19 (rear; front optional)
Remote ManagementSNMP agent, Modbus TCP/IP; dry relay contacts for generator integration
Display16×2 LCD with real-time status and event logging
Audible AlarmMute-able; selectable alert tones for AC loss, low battery, overload conditions
Surge Protection6 kVA peak transient immunity on input and output
Noise Level<65 dB(A) at 1 meter (full-load online operation)
Dimensions (Tower)400 mm H × 150 mm W × 350 mm D
Dimensions (2U Rack)88 mm H × 483 mm W × 450 mm D
Weight22 kg (battery included; rackmount adds ~2 kg)
Operating Temperature0–40°C (25°C nominal for full-load rating)
Operating Humidity20–80% RH (non-condensing)
EMC ComplianceCE (EN 62040-1, -2); FCC Class A
Safety StandardsIEC 62040-1 (UPS safety); IEC 60950-1 (electrical safety)
Launch DateQ4 2023

Available from Omnixon Global. Submit an RFQ and our team will confirm configuration and availability for your order.

Technical Specifications

BrandAcer
CategoryUPS & Power Protection
SKUACER-APCUPSRT1500
Part NumberAPC-UPS-RT1500
ConditionNew
Product LineAltos UPS
Model1500VA
UPS TypeDual-conversion online (VFI SS 111)
TopologyTrue online with rectifier, inverter, and static bypass
Input Voltage Range176–264 VAC (adjustable tolerance window)
Input Frequency50/60 Hz ±5 Hz (auto-sensing)
Output Voltage220/230/240 VAC (selectable) ±2%
Output Frequency50/60 Hz synchronized to inverter ±0.5 Hz
VA Rating1500 VA
Power Output1050 W at 0.7 power factor; up to 1500 W at 1.0 pf (resistive load)
Efficiency (Online Mode)≥92% (typical at 50% load)
Transfer Time (Mains to Battery)<1 ms (zero in online mode)
Battery TypeSealed lead-acid (VRLA), user-replaceable
Backup Runtime at Full Load8–12 minutes (dependent on battery configuration)
Runtime at 50% Load15–20 minutes
External Battery ModulesSupported; extends runtime to 45+ minutes at rated load
Deployment OptionsRack-mount (2U) or tower/pedestal configuration
CoolingForced-air convection with thermal management
Input Connectors1× IEC 60320 C20 (three-phase optional)
Output Connectors4× IEC 60320 C13 + 1× IEC 60320 C19 (rear; front optional)
Remote ManagementSNMP agent, Modbus TCP/IP; dry relay contacts for generator integration
Display16×2 LCD with real-time status and event logging
Audible AlarmMute-able; selectable alert tones for AC loss, low battery, overload conditions
Surge Protection6 kVA peak transient immunity on input and output
Noise Level<65 dB(A) at 1 meter (full-load online operation)
Dimensions (Tower)400 mm H × 150 mm W × 350 mm D
Dimensions (2U Rack)88 mm H × 483 mm W × 450 mm D
Weight22 kg (battery included; rackmount adds ~2 kg)
Operating Temperature0–40°C (25°C nominal for full-load rating)
Operating Humidity20–80% RH (non-condensing)
EMC ComplianceCE (EN 62040-1, -2); FCC Class A
Safety StandardsIEC 62040-1 (UPS safety); IEC 60950-1 (electrical safety)