About the Vertiv PowerUPS 9000 250kW UPS

The Vertiv PowerUPS 9000 250kW UPS from Vertiv is enterprise-grade UPS & Power Protection hardware built for data centers. 250kW three-phase online double-conversion UPS engineered for AI workloads and ultra-high-density data center power environments. Available in brand new condition. Available from Omnixon Global — contact our team to request a quote.

Technical Specifications

BrandVertiv
CategoryUPS & Power Protection
SKUVERT-PUPS9250K
Part NumberPUPS9-250K
ConditionNew
ModelPowerUPS 9000 250kW
TopologyOnline Double-Conversion (VFI, IEC 62040-3 Class VFI-SS-111)
Rated Output Power250 kW / 277.8 kVA
Input Voltage (Nominal)380 / 400 / 415 V AC three-phase, configurable
Input Voltage Range305–478 V AC (wide-input mode, no battery intervention)
Input Frequency Range45–65 Hz (auto-sensing)
Input Power Factor Correction>0.99 at full load (active PFC rectifier)
Input Current THDi<3% at full load
Output Voltage380 / 400 / 415 V AC three-phase (±1% regulation)
Output Frequency50 / 60 Hz ± 0.1% (free-running) / synchronised to bypass
Output Voltage THD<1% at linear load; <3% at 100% non-linear load
Peak Efficiency (Double-Conversion)97.2%
Peak Efficiency (Dynamic Online Mode)99.0%
Overload Capacity110% for 60 seconds; 125% for 10 seconds; 150% for 1 second
Battery Type SupportedVRLA, Li-Ion (via external battery cabinets), NiCd compatible
Battery Backup Time (at 100% load)Scalable via external battery modules; typically 5–30 minutes with standard cabinet configuration
Transfer Time (Utility to Battery)Zero (true online, no transfer)
Transfer Time (to Static Bypass)<2 ms
Parallel CapabilityUp to 4 units in parallel for N+1, 2N, or capacity expansion (up to 1 MW)
Communication InterfacesRS-232, USB, dry contacts, SNMP/HTTP (optional network management card), Modbus RTU/TCP
Form FactorFree-standing cabinet, front-access maintenance
Dimensions (H × W × D)1950 mm × 800 mm × 950 mm (approximate, without battery modules)
WeightApproximately 680 kg (unit only, varies with internal battery configuration)
Operating Temperature0°C to 40°C (full load); up to 45°C with derating
Relative Humidity5%–95% non-condensing
Audible Noise<72 dB(A) at 1 meter
Protection ClassIP20
CertificationsIEC 62040-1, IEC 62040-2, IEC 62040-3, CE, UL listed, RoHS compliant