Brand: Vertiv | Category: UPS & Power Protection
SKU: VERT-PUPS9250K | Part #: PUPS9-250K | MPN: PUPS9-250K
Contact for Pricing — Request a Quote
The Vertiv PowerUPS 9000 250kW UPS from Vertiv is enterprise-grade UPS & Power Protection hardware built for data centers. 250kW three-phase online double-conversion UPS engineered for AI workloads and ultra-high-density data center power environments. Available in brand new condition. Available from Omnixon Global — contact our team to request a quote.
| Brand | Vertiv |
| Category | UPS & Power Protection |
| SKU | VERT-PUPS9250K |
| Part Number | PUPS9-250K |
| Condition | New |
| Model | PowerUPS 9000 250kW |
| Topology | Online Double-Conversion (VFI, IEC 62040-3 Class VFI-SS-111) |
| Rated Output Power | 250 kW / 277.8 kVA |
| Input Voltage (Nominal) | 380 / 400 / 415 V AC three-phase, configurable |
| Input Voltage Range | 305–478 V AC (wide-input mode, no battery intervention) |
| Input Frequency Range | 45–65 Hz (auto-sensing) |
| Input Power Factor Correction | >0.99 at full load (active PFC rectifier) |
| Input Current THDi | <3% at full load |
| Output Voltage | 380 / 400 / 415 V AC three-phase (±1% regulation) |
| Output Frequency | 50 / 60 Hz ± 0.1% (free-running) / synchronised to bypass |
| Output Voltage THD | <1% at linear load; <3% at 100% non-linear load |
| Peak Efficiency (Double-Conversion) | 97.2% |
| Peak Efficiency (Dynamic Online Mode) | 99.0% |
| Overload Capacity | 110% for 60 seconds; 125% for 10 seconds; 150% for 1 second |
| Battery Type Supported | VRLA, Li-Ion (via external battery cabinets), NiCd compatible |
| Battery Backup Time (at 100% load) | Scalable via external battery modules; typically 5–30 minutes with standard cabinet configuration |
| Transfer Time (Utility to Battery) | Zero (true online, no transfer) |
| Transfer Time (to Static Bypass) | <2 ms |
| Parallel Capability | Up to 4 units in parallel for N+1, 2N, or capacity expansion (up to 1 MW) |
| Communication Interfaces | RS-232, USB, dry contacts, SNMP/HTTP (optional network management card), Modbus RTU/TCP |
| Form Factor | Free-standing cabinet, front-access maintenance |
| Dimensions (H × W × D) | 1950 mm × 800 mm × 950 mm (approximate, without battery modules) |
| Weight | Approximately 680 kg (unit only, varies with internal battery configuration) |
| Operating Temperature | 0°C to 40°C (full load); up to 45°C with derating |
| Relative Humidity | 5%–95% non-condensing |
| Audible Noise | <72 dB(A) at 1 meter |
| Protection Class | IP20 |
| Certifications | IEC 62040-1, IEC 62040-2, IEC 62040-3, CE, UL listed, RoHS compliant |