The Schneider Electric Symmetra PX 96kW Scalable to 160kW, without Bypass, Distribution, or Walls from Schneider Electric is enterprise-grade UPS & Power Protection hardware built for data centers. Enterprise-grade 96kW scalable 3-phase UPS chassis delivering modular redundancy and high density power protection for mission-critical data center infrastructure. Available in brand new condition. Schneider Electric ups & power protection products are trusted by enterprises and data centers worldwide. Available from Omnixon Global. Contact our sales team to request a quote.

Technical Specifications

BrandSchneider Electric
CategoryUPS & Power Protection
SKUSCHN-SY96K160H
Part NumberSY96K160H
ConditionNew
Product LineSymmetra PX
Form FactorModular scalable 3-phase UPS chassis
Power Rating - Minimum96 kW (96,000 W)
Power Rating - Maximum160 kW (160,000 W)
ScalabilityParallel-capable modular power modules with hot-swap architecture
Input Phase Configuration3-phase, 4-wire or 3-wire (configurable)
Output Phase Configuration3-phase, 4-wire or 3-wire (configurable)
Input Voltage Range380-480V AC (configurable per region)
Output Voltage Regulation±3% under dynamic load conditions
Frequency Support50/60 Hz ±5% input auto-detection with zero transfer time to battery
Transfer Time<4ms to battery inverter (no-break topology)
Battery TechnologyHot-swappable modular External Battery Modules (EBM)
Runtime ConfigurationConfigurable via EBM quantity (typical 5-30 minutes at full load with standard configurations)
Efficiency≥94% in double-conversion mode (AC-DC-AC)
Total Harmonic Distortion<3% output THD under non-linear loads
Bypass ArchitectureIntegrated static switch (no external bypass required)
Distribution IntegrationIntegrated output distribution (no separate PDU required)
Monitoring & ManagementSNMP v1/v2c/v3, Web-based GUI, dry contact relays, RS-232/485 serial interface
Predictive FeaturesBattery health monitoring, predictive maintenance alerts, load profiling analytics
MTBF>250,000 hours (field-measured enterprise deployments)
Environmental - TemperatureOperating 0-40°C; storage -20-60°C