Vertiv Liebert PCW Precision Cooling 100kW In-Row Unit

Vertiv Liebert PCW Precision Cooling 100kW In-Row Unit

Brand: Vertiv | Category: Server Racks & Enclosures

SKU: PCW10010C | Part #: PCW10010C | MPN: PCW10010C

Contact for Pricing — Request a Quote

Request a Quote Contact Us

About the Vertiv Liebert PCW Precision Cooling 100kW In-Row Unit

The Vertiv Liebert PCW Precision Cooling 100kW In-Row Unit (part number PCW10010C) is an in-row precision cooling unit designed for mounting between racks. It uses a liquid-to-air heat exchanger cooling method and is specified with a cooling capacity of 100kW.

The unit operates on 208-240V, 3-phase input power, with power consumption of up to 50kW. It is rated for a maximum ambient temperature of 35°C and a noise level of 75 dB(A) or less. A network management card is available as an optional control interface. The listed physical specifications include a 2U equivalent height, a weight of approximately 180 kg, and compatibility with 19-inch standard racks.

In-row cooling units of this type are placed alongside server racks to deliver cooling close to the IT equipment, making them suited to data centres and server rooms where rack-level heat removal is required.

Send the part number through our RFQ form and our team will reply within 48 hours.

Technical Specifications

BrandVertiv
CategoryServer Racks & Enclosures
SKUPCW10010C
Part NumberPCW10010C
ConditionNew
Product TypeIn-Row Precision Cooling Unit
Cooling Capacity100kW
Cooling MethodLiquid-to-Air Heat Exchanger
Maximum Ambient Temperature35°C
Noise Level≤75 dB(A)
Input Power208-240V, 3-Phase
Power ConsumptionUp to 50kW
Control InterfaceNetwork Management Card (Optional)
MountingIn-Row Mounting Between Racks
Height2U equivalent
WeightApproximately 180 kg
Rack Width Compatibility19-inch Standard Racks

Frequently Asked Questions about Vertiv Liebert PCW Precision Cooling 100kW In-Row Unit

What does the Vertiv Liebert PCW Precision Cooling 100kW In-Row Unit do?

The Vertiv Liebert PCW Precision Cooling 100kW In-Row Unit delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.

What are the headline specs of the Vertiv Liebert PCW Precision Cooling 100kW In-Row Unit?

Key specifications for the Vertiv Liebert PCW Precision Cooling 100kW In-Row Unit: new condition; product type In-Row Precision Cooling Unit; cooling capacity 100kW; cooling method Liquid-to-Air Heat Exchanger; maximum ambient temperature 35°C; noise level ≤75 dB(A); input power 208-240V, 3-Phase. Manufacturer part number PCW10010C. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.