Brand: Vertiv | Category: Rack PDUs
SKU: GW-96V060A-20-X | Part #: GW-96V060A-20-X | MPN: GW-96V060A-20-X
Contact for Pricing — Request a Quote
The Vertiv Geist Switched Rack PDU with Environmental Monitoring (part number GW-96V060A-20-X) is a 2U rack-mount power distribution unit. It accepts 208–240V AC input with a 60A input current rating and a total power capacity of 11.5 kW, delivered through 20 outlets in a configuration of twelve C13 and eight C19 receptacles.
Management features include switched outlets with individual outlet control, metering per phase, and temperature and humidity monitoring. The unit connects to the network through an Ethernet RJ45 interface and supports SNMP and Modbus TCP, so it can be integrated with existing monitoring and building management tools.
This PDU is suited to server racks and network cabinets in data centres and equipment rooms where administrators need to control power to individual devices, track phase-level load, and keep watch on environmental conditions within the rack.
Send the part number through our RFQ form and our team will reply within 48 hours.
| Brand | Vertiv |
| Category | Rack PDUs |
| SKU | GW-96V060A-20-X |
| Part Number | GW-96V060A-20-X |
| Condition | New |
| Manufacturer Part Number | GW-96V060A-20-X |
| Form Factor | 2U Rack |
| Input Voltage | 208–240V AC |
| Input Current Rating | 60A |
| Outlet Count | 20 |
| Outlet Configuration | (12) C13 & (8) C19 |
| Total Power Capacity | 11.5 kW |
| Management Features | Switched outlets, environmental monitoring |
| Environmental Sensors | Temperature and humidity monitoring |
| Security Features | Individual outlet control, metering per phase |
| Network Interface | Ethernet RJ45 |
| Protocol Support | SNMP, Modbus TCP |
The Vertiv Geist Switched Rack PDU with Environmental Monitoring UPDU GW-96V060A-20-X delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
Key specifications for the Vertiv Geist Switched Rack PDU with Environmental Monitoring UPDU GW-96V060A-20-X: new condition; manufacturer Vertiv; manufacturer part number GW-96V060A-20-X; form factor 2U Rack; input voltage 208–240V AC; input current rating 60A; outlet count 20. Manufacturer part number GW-96V060A-20-X. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.