Brand: Vertiv | Category: Rack PDUs
SKU: M1591 | Part #: M1591 | MPN: M1591
Contact for Pricing — Request a Quote
The Vertiv Geist Intelligent PDU M1591 is a monitored 3-phase rack power distribution unit designed for vertical rack mounting, occupying 2U. It provides 24 IEC 320 C13 outlets and is fed through an IEC 309 63A 3-phase input connector, with a rated current of 32A per phase and a maximum power of 22.08 kW across its 3-phase branch circuit configuration.
Monitoring covers branch-level voltage, current and power per phase, with real-time power metrics shown on an onboard LCD screen. Management is available over Ethernet and SNMP, and daisy-chain cascade capability allows multiple units to be monitored together. The unit operates from 0 to 50°C and measures 482 × 89 × 100 mm.
This PDU suits data centre and server room racks where higher-density equipment needs 3-phase power distribution along with per-phase visibility of power consumption.
Send the part number through our RFQ form and our team will reply within 48 hours.
| Brand | Vertiv |
| Category | Rack PDUs |
| SKU | M1591 |
| Part Number | M1591 |
| Condition | New |
| Manufacturer Part Number | M1591 |
| Form Factor | Vertical Rack Mount |
| Rack Units | 2U |
| Outlet Count | 24 × IEC 320 C13 |
| Input Connector | IEC 309 63A 3-phase |
| Rated Current | 32A per phase 3-phase |
| Maximum Power | 22.08 kW |
| Phase Configuration | 3-phase branch circuit |
| Monitoring Capability | Branch-level voltage, current, and power per phase |
| Onboard Display | LCD screen with real-time power metrics |
| Connectivity Feature | Daisy-chain cascade capability for multi-unit monitoring |
| Management Interface | Ethernet, SNMP |
| Operating Temperature | 0–50°C |
| Dimensions | 482 × 89 × 100 mm |
The Vertiv Geist Intelligent PDU Monitored 3-Phase PDU M1591 delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
Key specifications for the Vertiv Geist Intelligent PDU Monitored 3-Phase PDU M1591: new condition; manufacturer part number M1591; form factor Vertical Rack Mount; rack units 2U; outlet count 24 × IEC 320 C13; input connector IEC 309 63A 3-phase; rated current 32A per phase 3-phase. Manufacturer part number M1591. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.