APC Rack PDU 9000 Switched, ZeroU, 11.5KW, 200-240V, (21) C13/C15 & (3) C19/C21 (*poa)

APC Rack PDU 9000 Switched, ZeroU, 11.5KW, 200-240V, (21) C13/C15 & (3) C19/C21 (*poa)

Brand: APC | Category: Rack PDUs

SKU: APDU9981NA3 | Part #: APDU9981NA3 | MPN: APDU9981NA3

Contact for Pricing — Request a Quote

Request a Quote Contact Us

About the APC Rack PDU 9000 Switched, ZeroU, 11.5KW, 200-240V, (21) C13/C15 & (3) C19/C21 (*poa)

The APC Rack PDU 9000 Switched (part number APDU9981NA3) is a ZeroU rack power distribution unit rated at 11.5 kW. It provides 24 AC outlets in total: 21 C13/C15 and 3 C19/C21. This lets a single unit serve a mix of equipment power cords within a rack.

The PDU is a three-phase unit with an IEC 60309 20 A 3P + N + PE input connection and a nominal input voltage of 415 V. It supports a maximum power of 11,500 W, a load capacity of 11,000 VA and a maximum current of 16 A. Output voltage is 208 V or 240 V, with a nominal output of 200–208 V, and the AC input frequency is 50–60 Hz. The unit has a 1.82 m cable and a black finish.

As a switched, zero-U rack PDU, it is used in server racks and network cabinets in data centres and equipment rooms to distribute power to installed IT equipment.

Send the part number through our RFQ form and our team will reply within 48 hours.

Technical Specifications

BrandAPC
CategoryRack PDUs
SKUAPDU9981NA3
Part NumberAPDU9981NA3
ConditionNew
Input connection typeIEC 60309 20 A 3P + N + PE
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
AC outlets quantity24 AC outlet(s)
Cable length1.82 m
Maximum power11500 W
Number of phases3
Load capacity11000 VA
Output voltage208 V; 240 V
Nominal output voltage200 - 208 V
Maximum current16 A
AC input frequency50 - 60 Hz
Nominal input voltage415 3 phases
Sustainable packagingNo
Packaging recycled materialsRecycled cardboard
SCIP number31346aed-552c-4a16-81d9-e683a383b6da
Removable batteryYes
Preferred mounting positionno preference
Take-back systemNo
Packaging without single use plasticNo
Product colourBlack
MountingVertical
Rack capacity0U
TypeThree-phase
PDU typesSwitched
Non-operating altitude0 - 15240 m
Operating altitude0 - 3048 m
Operating relative humidity (H-H)5 - 95%
Storage relative humidity (H-H)5 - 95%
Storage temperature (T-T)-25 - 65 °C
Operating temperature (T-T)-5 - 60 °C
Weight7 kg
Height1791 mm
Depth46 mm
Width55 mm
CertificationcUL listed; FCC part 15 class A; PSE
Waste Electrical and Electronic Equipment (WEEE) complianceYes
Compliance certificatesRoHS, REACH, WEEE

Frequently Asked Questions about APC Rack PDU 9000 Switched, ZeroU, 11.5KW, 200-240V, (21) C13/C15 & (3) C19/C21 (*poa)

What does the APC Rack PDU 9000 Switched, ZeroU, 11.5KW, 200-240V, (21) C13/C15 & (3) C19/C21 (*poa) do?

The APC Rack PDU 9000 Switched, ZeroU, 11.5KW, 200-240V, (21) C13/C15 & (3) C19/C21 (*poa) delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.

What are the headline specs of the APC Rack PDU 9000 Switched, ZeroU, 11.5KW, 200-240V, (21) C13/C15 & (3) C19/C21 (*poa)?

Key specifications for the APC Rack PDU 9000 Switched, ZeroU, 11.5KW, 200-240V, (21) C13/C15 & (3) C19/C21 (*poa): new condition; input connection type IEC 60309 20 A 3P + N + PE; ac outlet types C13 coupler, C15 coupler, C19 coupler, C21 coupler; ac outlets quantity 24 AC outlet(s); cable length 1.82 m; maximum power 11500 W; number of phases 3. Manufacturer part number APDU9981NA3. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.