Brand: Panduit | Category: Rack PDUs
SKU: PAND-P36G19M | Part #: P36G19M | MPN: P36G19M
Contact for Pricing — Request a Quote
The Panduit SmartZone P36G19M is a 17.3 kW, 3-phase managed rack PDU engineered for high-density data center deployments where centralized power visibility and control are critical. Built around Panduit's SmartZone gateway architecture, the unit connects to a SmartZone G5 or compatible gateway controller, enabling unified DCIM-level power monitoring across entire rows or rooms of racks without requiring a dedicated IP address per PDU. The P36G19M accepts a 3-phase 208 V input via a CS8365C locking plug and distributes power through 36 individually monitored NEMA 5-20R outlets arranged across three phase branches, providing granular per-outlet current measurement to support accurate capacity planning and load balancing.
The PDU provides real-time measurement of inlet voltage, current, and power (kW and kVA) at both the unit and per-branch levels, feeding data upstream through the SmartZone gateway's encrypted communication bus. This aggregated telemetry integrates with leading DCIM platforms and building management systems via the gateway's SNMP v1/v2c/v3, Modbus TCP, and RESTful API interfaces, making it well suited for facilities pursuing consolidated power chain analytics from utility meter to server PSU. Threshold-based alerting can be configured for overload conditions on each branch, supporting proactive capacity management before circuit-level events occur.
Designed in a 0U vertical form factor for tool-less side or rear mounting within standard 600 mm or 800 mm wide two-post and four-post open-frame racks and enclosed cabinets, the P36G19M minimizes U-space consumption while maximizing outlet density for compute, storage, and networking equipment. Its inclusion in Panduit's SmartZone ecosystem enables a single gateway to manage multiple PDUs, consolidating power data collection and reducing infrastructure overhead in large-scale enterprise, colocation, and cloud-adjacent environments.
| Manufacturer | Panduit |
| Manufacturer Part Number | P36G19M |
| Series | SmartZone Managed Rack PDU |
| Management Architecture | SmartZone gateway-managed (requires SmartZone G5 or compatible gateway; no dedicated IP address per PDU) |
| Total Power Capacity | 17.3 kW |
| Input Phase | 3-Phase |
| Input Voltage | 208 V AC (3-phase Wye) |
| Input Current | 48 A |
| Input Plug | CS8365C (locking, 4-wire) |
| Input Frequency | 50/60 Hz |
| Total Outlet Count | 36 |
| Outlet Type | NEMA 5-20R |
| Phase Branches | 3 (A, B, C — 12 outlets per branch) |
| Metering Granularity | Per-outlet current monitoring; per-branch and unit-level voltage, current, kW, and kVA |
| Communication Interface | SmartZone daisy-chain bus (RJ-45); protocols exposed via gateway: SNMP v1/v2c/v3, Modbus TCP, RESTful API |
| Form Factor | 0U Vertical |
| Mounting | Vertical side or rear mount; compatible with 600 mm and 800 mm wide racks and cabinets |
| Operating Temperature | 0 °C to 45 °C |
| Operating Humidity | 0% to 95% RH, non-condensing |
Available from Omnixon Global. Submit an RFQ and our team will confirm configuration and availability for your order.
| Brand | Panduit |
| Category | Rack PDUs |
| SKU | PAND-P36G19M |
| Part Number | P36G19M |
| Condition | New |
| Manufacturer Part Number | P36G19M |
| Series | SmartZone Managed Rack PDU |
| Management Architecture | SmartZone gateway-managed (requires SmartZone G5 or compatible gateway; no dedicated IP address per PDU) |
| Total Power Capacity | 17.3 kW |
| Input Phase | 3-Phase |
| Input Voltage | 208 V AC (3-phase Wye) |
| Input Current | 48 A |
| Input Plug | CS8365C (locking, 4-wire) |
| Input Frequency | 50/60 Hz |
| Total Outlet Count | 36 |
| Outlet Type | NEMA 5-20R |
| Phase Branches | 3 (A, B, C — 12 outlets per branch) |
| Metering Granularity | Per-outlet current monitoring; per-branch and unit-level voltage, current, kW, and kVA |
| Communication Interface | SmartZone daisy-chain bus (RJ-45); protocols exposed via gateway: SNMP v1/v2c/v3, Modbus TCP, RESTful API |
| Form Factor | 0U Vertical |
| Mounting | Vertical side or rear mount; compatible with 600 mm and 800 mm wide racks and cabinets |
| Operating Temperature | 0 °C to 45 °C |
| Operating Humidity | 0% to 95% RH, non-condensing |
The Panduit SmartZone Managed Rack PDU 17.3kW 3-Phase delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
The Panduit SmartZone Managed Rack PDU 17.3kW 3-Phase delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
The Panduit SmartZone Managed Rack PDU 17.3kW 3-Phase delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
Key specifications for the Panduit SmartZone Managed Rack PDU 17.3kW 3-Phase: new condition; manufacturer Panduit; manufacturer part number P36G19M; series SmartZone Managed Rack PDU; management architecture SmartZone gateway-managed (requires SmartZone G5 or compatible gateway; no dedicated IP address per PDU); total power capacity 17.3 kW; input phase 3-Phase. Manufacturer part number P36G19M. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.
Key specifications for the Panduit SmartZone Managed Rack PDU 17.3kW 3-Phase: new condition; manufacturer Panduit; manufacturer part number P36G19M; series SmartZone Managed Rack PDU; management architecture SmartZone gateway-managed (requires SmartZone G5 or compatible gateway; no dedicated IP address per PDU); total power capacity 17.3 kW; input phase 3-Phase. Manufacturer part number P36G19M. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.