INROW RD, 600MM AIR COOLED, 380-415V, 50/60HZ, WITH HUMIDIFIER

INROW RD, 600MM AIR COOLED, 380-415V, 50/60HZ, WITH HUMIDIFIER

Brand: APC | Category: Server Racks & Enclosures

SKU: ACRD602P | Part #: ACRD602P | MPN: ACRD602P

Contact for Pricing — Request a Quote

Request a Quote Contact Us

About the INROW RD, 600MM AIR COOLED, 380-415V, 50/60HZ, WITH HUMIDIFIER

Active Airflow Control

Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.

Active response control

Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.

Air filtration

Removes dirt and other particulates from the intake air for cleaner supply air.

Architecturally neutral

Unobtrusive design and coloring, blends in with the surroundings.

Capacity Control

Cooling system will operate from 0 - 100% of the rated capacity to maintain rack inlet temperatures and reduce operational costs at varying heat loads.

Casters

Provides flexibility to move the unit to wherever cooling is required.

Containment system compatible

The unit can be combined with a Rack or Hot Aisle Containment System to eliminate hot air mixing and maximize cooling efficiency

Continuous current monitoring

Permits a continuous monitoring of the compressor’s absorbed current to signal possible discrepancies with the default values (Optional).

Direct drive motors

Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.

Ease of Use

Simplifies future planning by allowing side to side equipment to be placed anywhere in the data center.

Easy to install

Innovative design allows for fast, easy installation by almost anybody.

Efficiency

Increases the capacity of the air conditioner by supplying a warmer return air temperature.

Electric Reheat

Prevents overcooling during dehumidification.

Electronic expansion valve

Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring

Electronically Commutated Fans

Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.

Enclosure system compatible

Specifically designed to work with Netshelter Enclosures.

Fan guards

A safety measure that provides protection from the fan opening by covering the inlet.

Fault-tolerant fan system

In the event of a fan failure, the remaining fan(s) will continue to operate.

Field replaceable components

Fans and electronics module can be readily replaced without uninstalling the unit.

Flexibility

Support for varying aisle widths, rack heights, rack depths, and single rows. Supports hot and cold aisle containment

Front service access

The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.

Green Refrigerant

Environmentally friendly refrigerant that can offer LEED points.

Hardwire capable

For installations where hard wiring is required or prefered.

Head pressure control

Modulates refrigerant head pressure to protect from coil freeze.

High Sensible-to-Total Cooling Ratio

Achieved by careful sizing of heat exchanger coils.

Horizontal airflow pattern

Removes heat close to the source of generation in the hot aisle and distributes cold air to the front of the racks in the cold aisle.

Humidifier

Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure steam canister maintains consistent capacity output, and requires very little or no scheduled maintenance.

Increased capacity

Higher rate of heat removal allows more equipment to be installed in each rack.

Local area network

Creates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations

Minimizes Air Mixing

Delivers cool, conditioned air directly to the inlet of IT equipment.

Modular strategy

Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expeditures and provides deferred investment throughout the life of the facility.

Network interface

Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.

Operational efficiency

Warmer entering air temperatures reduce both the required amount of humidification and the demand for costly reheat.

Predictable cooling

Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

Predictive failure notification

Maximizes system availability by providing early warning of required fan or filter replacement.

Programmable input/output contacts

Allows device contacts to be connected to the air conditioner and mapped to customer outputs or system alarms.

Rack Inlet Temperature Control

Reduces the risk of hot spots at the rack level

Real-Time Capacity Monitoring

Real-time display of current and available cooling.

Rear containment

Ensures server exhaust air is returned to the InRow cooling units for maximum cooling predictability.

Row-based architecture

Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Scalable Design

Modular design provides scalable solutions to add cooling as demand increases.

Small Footprint

Efficient use of space with a small footprint provides the ability for the unit to be placed in a corner or even installed into a partitioned space.

Temperature Display

Monitors and displays temperature to prevent overheating.

Touch-screen GUI

Enables easy configuration, full monitoring, and event logging

Technical Specifications

BrandAPC
CategoryServer Racks & Enclosures
SKUACRD602P
Part NumberACRD602P
ConditionNew
Product colourBlack
Weight402 kg
Height1991 mm
Depth1070 mm
Width600 mm