Brand: Eaton | Category: Rack PDUs
SKU: EATO-EMAT32 | Part #: EMAT32 | MPN: EMAT32
Contact for Pricing — Request a Quote
The Eaton G4 Managed Rack PDU (EMAT32) represents the fourth generation of Eaton's intelligent power distribution architecture, delivering 17.3kW of three-phase power at 415V across 36 outlets within a standard 0U vertical rack form factor. Built on the new G4 platform, it incorporates a color LCD display for at-a-glance power visibility and a Gigabit Ethernet management interface, enabling faster data polling and more responsive integration with modern data center infrastructure management (DCIM) platforms. Per-outlet switching and metering provide granular load control and real-time power consumption data at the individual circuit level.
Designed for high-density compute environments, the EMAT32 supports remote outlet-level monitoring, switching, and sequencing through its embedded network management card, compatible with SNMP, Modbus, and RESTful API protocols. The unit provides inlet-level and branch-level current and power metering, enabling accurate capacity planning and load balancing across three-phase infrastructure. Environmental monitoring ports allow the connection of temperature and humidity sensors, extending visibility beyond power to broader rack conditions.
The G4 platform targets enterprise data centers, colocation facilities, and high-performance computing deployments where dense server, storage, and networking loads demand precise power management, remote remediation capability, and seamless integration into existing IT operations toolchains. The combination of high-amperage three-phase input, a large outlet count, and Gigabit management connectivity positions the EMAT32 as a leading solution for operators consolidating power infrastructure in modern hyperscale and enterprise rack environments.
| Manufacturer | Eaton |
| Manufacturer Part Number | EMAT32 |
| Product Line | G4 Managed Rack PDU |
| Input Voltage | 415V three-phase |
| Input Phase Configuration | 3-phase |
| Maximum Load | 17.3kW |
| Input Connection | IEC 60309 32A 3P+N+E |
| Total Outlet Count | 36 |
| Outlet Types | IEC C13 and IEC C19 |
| Form Factor | 0U vertical |
| Management Interface | Gigabit Ethernet (10/100/1000) |
| Supported Protocols | SNMP v1/v2c/v3, Modbus TCP, RESTful API |
| Display | Color LCD |
| Metering Granularity | Per-outlet, per-branch, and inlet-level current and power metering |
| Outlet Switching | Per-outlet remote switching and sequencing |
| Environmental Monitoring | External sensor port(s) for temperature and humidity sensors |
| Platform Generation | G4 |
| Mounting | Vertical 0U rack mount |
Available from Omnixon Global. Submit an RFQ and our team will confirm configuration and availability for your order.
| Brand | Eaton |
| Category | Rack PDUs |
| SKU | EATO-EMAT32 |
| Part Number | EMAT32 |
| Condition | New |
| Manufacturer Part Number | EMAT32 |
| Product Line | G4 Managed Rack PDU |
| Input Voltage | 415V three-phase |
| Input Phase Configuration | 3-phase |
| Maximum Load | 17.3kW |
| Input Connection | IEC 60309 32A 3P+N+E |
| Total Outlet Count | 36 |
| Outlet Types | IEC C13 and IEC C19 |
| Form Factor | 0U vertical |
| Management Interface | Gigabit Ethernet (10/100/1000) |
| Supported Protocols | SNMP v1/v2c/v3, Modbus TCP, RESTful API |
| Display | Color LCD |
| Metering Granularity | Per-outlet, per-branch, and inlet-level current and power metering |
| Outlet Switching | Per-outlet remote switching and sequencing |
| Environmental Monitoring | External sensor port(s) for temperature and humidity sensors |
| Platform Generation | G4 |
| Mounting | Vertical 0U rack mount |
The Eaton G4 Managed Rack PDU 17.3kW 3PH 415V 36-Outlet delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
The Eaton G4 Managed Rack PDU 17.3kW 3PH 415V 36-Outlet delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
The Eaton G4 Managed Rack PDU 17.3kW 3PH 415V 36-Outlet delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
Key specifications for the Eaton G4 Managed Rack PDU 17.3kW 3PH 415V 36-Outlet: new condition; manufacturer Eaton; manufacturer part number EMAT32; product line G4 Managed Rack PDU; input voltage 415V three-phase; input phase configuration 3-phase; maximum load 17.3kW. Manufacturer part number EMAT32. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.
Key specifications for the Eaton G4 Managed Rack PDU 17.3kW 3PH 415V 36-Outlet: new condition; manufacturer Eaton; manufacturer part number EMAT32; product line G4 Managed Rack PDU; input voltage 415V three-phase; input phase configuration 3-phase; maximum load 17.3kW. Manufacturer part number EMAT32. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.