Eaton ePDU G3 Managed 1U MA10L6 2P Input Rack PDU MA10L6

Eaton ePDU G3 Managed 1U MA10L6 2P Input Rack PDU MA10L6

Brand: Eaton | Category: Rack PDUs

SKU: EATO-MA10L6 | Part #: MA10L6 | MPN: MA10L6

Contact for Pricing — Request a Quote

Request a Quote Contact Us

About the Eaton ePDU G3 Managed 1U MA10L6 2P Input Rack PDU MA10L6

The Eaton ePDU G3 Managed 1U (model MA10L6) is a rack-mounted power distribution unit engineered for data centers and IT infrastructure requiring real-time power visibility and environmental awareness. This 1U form-factor device provides dual input (2P) capability with managed outlet-level metering, enabling granular power consumption tracking and remote power cycling of individual circuits. The integrated environmental monitoring inputs support temperature and humidity sensors, allowing operators to correlate power events with thermal conditions and prevent equipment failures before they occur.

Architecturally, the MA10L6 combines a robust switched PDU platform with Eaton's EMP (Eaton Management Portal) integration and standards-based SNMP v3 communication. The web interface provides real-time dashboarding, threshold-based alerting, and audit-logging capabilities suitable for regulated environments including healthcare IT and telecommunications. Redundant dual power inputs ensure availability during single-source failures, while the compact 1U design optimizes rack real estate in space-constrained deployments.

The device is notable for its tight integration with Eaton UPS systems and power management ecosystems, combined with environmental sensor extensibility that enables holistic infrastructure monitoring. Launched in Q3 2020, the G3 generation represents Eaton's latest managed PDU architecture, widely adopted for its reliability, alerting sophistication, and compatibility with enterprise IT management platforms.

Ideal for

  • Healthcare IT infrastructure requiring SOX/HIPAA-compliant power auditing and thermal monitoring to prevent medical equipment failures
  • Telecommunications NOCs managing multi-rack deployments with per-outlet power metering and automated failover alerts
  • Financial services data centers needing environmental correlation analysis during power anomalies and incident response
  • University research computing clusters requiring real-time power budgeting and environmental data collection across distributed racks
  • Managed service provider colocation environments with tenant-level power isolation, metering, and per-circuit remote reboot capabilities
  • Disaster recovery facilities requiring synchronized power management across redundant sites via centralized SNMP monitoring

Technical specifications

ManufacturerEaton
ModelMA10L6
Product LineePDU G3 Managed
Form Factor1U Rack Mount
Input ConfigurationDual Input (2P)
Input ConnectorsIEC C20 (dual)
Output Outlets10x IEC C13 outlets
Outlet ControlRemote switched per-outlet (SNMP/web)
Nominal Input Voltage200-240V AC
Input Frequency50-60 Hz
Rated Input Current16A per input
Maximum Output Power3680W (dual input @ 240V)
Outlet MeteringReal-time per-outlet voltage, current, power, energy
Management InterfaceGigabit Ethernet RJ45
Management ProtocolSNMP v1/v2c/v3, HTTP/HTTPS web interface
Environmental Inputs2x analog sensor inputs (temperature, humidity, etc.)
Data LoggingLocal event log with syslog export capability
Alert CapabilitiesThreshold-based SNMP traps, email, syslog notifications
EMP IntegrationFull compatibility with Eaton Management Portal
Physical Dimensions1U x 19" rack width x 450mm depth
Operating Temperature0-50°C
Humidity Range10-90% non-condensing
Network SecuritySNMP v3 authentication, HTTPS encryption, IP access control lists

Available from Omnixon Global. Submit an RFQ and our team will confirm configuration and availability for your order.

Technical Specifications

BrandEaton
CategoryRack PDUs
SKUEATO-MA10L6
Part NumberMA10L6
ConditionNew
ModelMA10L6
Product LineePDU G3 Managed
Form Factor1U Rack Mount
Input ConfigurationDual Input (2P)
Input ConnectorsIEC C20 (dual)
Output Outlets10x IEC C13 outlets
Outlet ControlRemote switched per-outlet (SNMP/web)
Nominal Input Voltage200-240V AC
Input Frequency50-60 Hz
Rated Input Current16A per input
Maximum Output Power3680W (dual input @ 240V)
Outlet MeteringReal-time per-outlet voltage, current, power, energy
Management InterfaceGigabit Ethernet RJ45
Management ProtocolSNMP v1/v2c/v3, HTTP/HTTPS web interface
Environmental Inputs2x analog sensor inputs (temperature, humidity, etc.)
Data LoggingLocal event log with syslog export capability
Alert CapabilitiesThreshold-based SNMP traps, email, syslog notifications
EMP IntegrationFull compatibility with Eaton Management Portal
Physical Dimensions1U x 19" rack width x 450mm depth
Operating Temperature0-50°C
Humidity Range10-90% non-condensing
Network SecuritySNMP v3 authentication, HTTPS encryption, IP access control lists