The APC Rack PDU 2G Metered (AP8865) is a zero-rack-unit, vertically mounted three-phase power distribution unit engineered for high-density data center deployments requiring branch-circuit-level power visibility. Drawing from a 30A, three-phase input at 208V (providing approximately 8.3kW of usable power), the unit distributes power across 42 C13 outlets and 6 C19 outlets, delivering flexible connectivity for a broad mix of server, storage, and networking loads. Integrated current metering at the input branch level allows operations teams to monitor load in real time via the built-in display, enabling proactive capacity management and preventing costly over-provisioning or unplanned outages.
The second-generation (2G) intelligence platform embedded in the AP8865 provides network-accessible monitoring through a dedicated RJ-45 Ethernet management port, exposing real-time amp, volt, and watt readings through a web interface, SNMPv1/v3, and Telnet/SSH. The unit supports APC's ecosystems including StruxureWare Data Center Expert and EcoStruxure IT for centralized fleet monitoring across large environments. Outlet-level switching is not included in this metered variant, maintaining a straightforward, reliable distribution architecture preferred in environments where simplicity and density take precedence over granular outlet control.
Designed for vertical 0U mounting within standard 600mm or deeper two-post or four-post racks and enclosures, the AP8865 does not consume any rack unit space, preserving valuable vertical real estate for compute and storage equipment. Its NEMA L15-30P input plug mates with compatible PDPs and transfer switches common in three-phase North American data center infrastructure. The unit is well-suited to colocation facilities, enterprise on-premises data centers, and high-performance computing rows where three-phase power distribution and accurate current monitoring are operational requirements.
| Manufacturer | APC by Schneider Electric |
| Manufacturer Part Number | AP8865 |
| PDU Generation | 2G (Second Generation) |
| PDU Type | Metered, 0U Vertical Rack Mount |
| Input Voltage | 208V AC, 3-Phase |
| Input Amperage | 30A |
| Maximum Output Power | 8.3 kW |
| Input Plug | NEMA L15-30P |
| Total Outlets | 48 |
| Outlet Types | 42 x IEC 320 C13, 6 x IEC 320 C19 |
| Outlet Groups | 3 (one per phase, 14 x C13 + 2 x C19 per group) |
| Input Phases | 3-Phase |
| Input Frequency | 50/60 Hz |
| Metering | Input current metering per phase with local LED display |
| Network Management Interface | RJ-45 10/100 Mbps Ethernet (dedicated management port) |
| Supported Protocols | SNMPv1, SNMPv3, HTTP, HTTPS, Telnet, SSH, Modbus TCP |
| Form Factor | 0U Vertical |
| Mounting | Vertical, 0U (side or rear panel of rack); compatible with 2-post and 4-post enclosures |
| Operating Temperature | 0°C to 45°C (32°F to 113°F) |
| Operating Humidity | 0–95% non-condensing |
| Cord Length (Input) | 3.05 m (10 ft) |
Available from Omnixon Global. Submit an RFQ and our team will confirm configuration and availability for your order.
| Brand | APC |
| Category | Rack PDUs |
| SKU | APC-AP8865 |
| Part Number | AP8865 |
| Condition | New |
| Manufacturer Part Number | AP8865 |
| PDU Generation | 2G (Second Generation) |
| PDU Type | Metered, 0U Vertical Rack Mount |
| Input Voltage | 208V AC, 3-Phase |
| Input Amperage | 30A |
| Maximum Output Power | 8.3 kW |
| Input Plug | NEMA L15-30P |
| Total Outlets | 48 |
| Outlet Types | 42 x IEC 320 C13, 6 x IEC 320 C19 |
| Outlet Groups | 3 (one per phase, 14 x C13 + 2 x C19 per group) |
| Input Phases | 3-Phase |
| Input Frequency | 50/60 Hz |
| Metering | Input current metering per phase with local LED display |
| Network Management Interface | RJ-45 10/100 Mbps Ethernet (dedicated management port) |
| Supported Protocols | SNMPv1, SNMPv3, HTTP, HTTPS, Telnet, SSH, Modbus TCP |
| Form Factor | 0U Vertical |
| Mounting | Vertical, 0U (side or rear panel of rack); compatible with 2-post and 4-post enclosures |
| Operating Temperature | 0°C to 45°C (32°F to 113°F) |
| Operating Humidity | 0–95% non-condensing |
| Cord Length (Input) | 3.05 m (10 ft) |