Omnixon Global
APC NetShelter Rack PDU Advanced Switched Metered 8.6kW 1-Phase

APC NetShelter Rack PDU Advanced Switched Metered 8.6kW 1-Phase

Brand: APC | Category: Rack PDUs

SKU: APC-APDU10250SM | Part #: APDU10250SM | MPN: APDU10250SM

Contact for Pricing — Request a Quote

Request a Quote Contact Us

About the APC NetShelter Rack PDU Advanced Switched Metered 8.6kW 1-Phase

The APC NetShelter Rack PDU Advanced Switched Metered (APDU10250SM) is a 1-phase, high-density power distribution unit engineered for enterprise data center cabinets and high-performance computing environments. Built around outlet-level switching and metering capabilities, it enables granular remote power control of individual receptacles, allowing IT and facilities teams to cycle power to specific devices, enforce load balancing, and eliminate the need for physical access to the rack during remediation events. The unit delivers up to 8.6 kW of usable power from a single-phase input and is designed to operate in the elevated ambient temperatures common in modern high-density deployments.

At the architectural level, the APDU10250SM integrates per-outlet current metering alongside unit-level and bank-level metering, providing real-time visibility into power consumption across the full receptacle set. This multi-tier metering hierarchy feeds into APC's EcoStruxure IT and Data Center Expert management platforms via a network-connected management card, supporting SNMP, Modbus TCP, and RESTful API interfaces for integration with existing DCIM, ITSM, and monitoring toolchains. Outlet-level switching is independently controllable, with configurable power-on sequencing and time delays to manage inrush current during scheduled restarts or failover events.

The unit is housed in a 0U vertical form factor suited to standard 600 mm and 750 mm wide NetShelter enclosures, preserving rack unit space for active compute and networking equipment. Its robust thermal rating supports continuous operation in environments where ambient temperatures regularly exceed typical data center baselines, making it a practical choice for edge deployments, co-location cabinets, and high-density HPC racks where thermal margins are constrained. The combination of remote outlet control, multi-level metering, and enterprise management integration positions the APDU10250SM as a core infrastructure component for organizations prioritizing operational visibility and remote management capability.

Ideal for

  • Remote power cycling of individual servers or network devices in unstaffed edge or co-location facilities, eliminating the need for an on-site technician during a software hang or firmware recovery event
  • Granular load balancing across a high-density rack by monitoring per-outlet current in real time and redistributing workloads to prevent circuit overloads in single-phase cabinets approaching capacity
  • Scheduled power sequencing during planned maintenance windows, using configurable outlet-level time delays to manage inrush current when bringing a full rack of servers back online simultaneously
  • Integration with DCIM platforms such as APC EcoStruxure IT or third-party tools via SNMP and RESTful API for unified power consumption reporting, capacity planning, and automated alerting
  • High-density HPC and AI inference rack deployments where elevated ambient temperatures require PDUs rated for operation above standard data center thermal baselines without derating
  • Compliance and audit support in regulated enterprise environments, where per-outlet metering data provides accurate, timestamped power consumption records for energy reporting and chargeback models

Technical specifications

ManufacturerAPC by Schneider Electric
Manufacturer Part NumberAPDU10250SM
Product LineNetShelter Rack PDU Advanced
PDU TypeSwitched Metered
Phase Configuration1-Phase
Maximum Output Power8.6 kW
Input Voltage200–240 V AC
Input Frequency50/60 Hz
Input ConnectionIEC 309 (IEC 60309) 2P+E, 32 A
Form Factor0U Vertical
Outlet SwitchingPer-outlet individual switching with remote control
Metering LevelsPer-outlet, per-bank, and unit-level current and power metering
Management InterfaceEmbedded network management — supports SNMP v1/v2c/v3, Modbus TCP, RESTful API
Compatible Management PlatformsAPC EcoStruxure IT, APC Data Center Expert
Operating Temperature0 °C to 60 °C (32 °F to 140 °F)
Mounting OrientationVertical, 0U rack mount
Compatible EnclosuresAPC NetShelter SX, SV, and CX series; standard EIA 600 mm and 750 mm wide cabinets
Safety CertificationsUL Listed, CE Marked

Available from Omnixon Global. Submit an RFQ and our team will confirm configuration and availability for your order.

Technical Specifications

BrandAPC
CategoryRack PDUs
SKUAPC-APDU10250SM
Part NumberAPDU10250SM
ConditionNew
Manufacturer Part NumberAPDU10250SM
Product LineNetShelter Rack PDU Advanced
PDU TypeSwitched Metered
Phase Configuration1-Phase
Maximum Output Power8.6 kW
Input Voltage200–240 V AC
Input Frequency50/60 Hz
Input ConnectionIEC 309 (IEC 60309) 2P+E, 32 A
Form Factor0U Vertical
Outlet SwitchingPer-outlet individual switching with remote control
Metering LevelsPer-outlet, per-bank, and unit-level current and power metering
Management InterfaceEmbedded network management — supports SNMP v1/v2c/v3, Modbus TCP, RESTful API
Compatible Management PlatformsAPC EcoStruxure IT, APC Data Center Expert
Operating Temperature0 °C to 60 °C (32 °F to 140 °F)
Mounting OrientationVertical, 0U rack mount
Compatible EnclosuresAPC NetShelter SX, SV, and CX series; standard EIA 600 mm and 750 mm wide cabinets
Safety CertificationsUL Listed, CE Marked

Frequently Asked Questions about APC NetShelter Rack PDU Advanced Switched Metered 8.6kW 1-Phase

What does the APC NetShelter Rack PDU Advanced Switched Metered 8.6kW 1-Phase do?

The APC NetShelter Rack PDU Advanced Switched Metered 8.6kW 1-Phase delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.

What does the APC NetShelter Rack PDU Advanced Switched Metered 8.6kW 1-Phase do?

The APC NetShelter Rack PDU Advanced Switched Metered 8.6kW 1-Phase delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.

What does the APC NetShelter Rack PDU Advanced Switched Metered 8.6kW 1-Phase do?

The APC NetShelter Rack PDU Advanced Switched Metered 8.6kW 1-Phase delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.

What are the headline specs of the APC NetShelter Rack PDU Advanced Switched Metered 8.6kW 1-Phase?

Key specifications for the APC NetShelter Rack PDU Advanced Switched Metered 8.6kW 1-Phase: new condition; manufacturer APC by Schneider Electric; manufacturer part number APDU10250SM; product line NetShelter Rack PDU Advanced; pdu type Switched Metered; phase configuration 1-Phase; maximum output power 8.6 kW. Manufacturer part number APDU10250SM. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.

What are the headline specs of the APC NetShelter Rack PDU Advanced Switched Metered 8.6kW 1-Phase?

Key specifications for the APC NetShelter Rack PDU Advanced Switched Metered 8.6kW 1-Phase: new condition; manufacturer APC by Schneider Electric; manufacturer part number APDU10250SM; product line NetShelter Rack PDU Advanced; pdu type Switched Metered; phase configuration 1-Phase; maximum output power 8.6 kW. Manufacturer part number APDU10250SM. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.