APC NetShelter Rack PDU Advanced Metered 11.0kW Single-Phase

APC NetShelter Rack PDU Advanced Metered 11.0kW Single-Phase

Brand: Schneider Electric | Category: Rack PDUs

SKU: SCHN-APDU9101M | Part #: APDU9101M | MPN: APDU9101M

Contact for Pricing — Request a Quote

Request a Quote Contact Us

About the APC NetShelter Rack PDU Advanced Metered 11.0kW Single-Phase

The APC NetShelter Rack PDU Advanced Metered (APDU9101M) is a single-phase, high-density intelligent power distribution unit engineered for enterprise data center and colocation rack deployments requiring granular power visibility. Built on Schneider Electric's Advanced PDU platform, it delivers 11.0 kW of total capacity across a metered architecture that provides real-time inlet-level current, voltage, power (kW), apparent power (kVA), and energy consumption (kWh) readings accessible via an integrated local display and remote network interface. The unit ships with onboard environmental sensors and supports Schneider Electric's EcoStruxure IT ecosystem, enabling integration with DCIM platforms for centralized monitoring and capacity planning.

The APDU9101M is designed around a robust vertical form factor suited to standard 0U rack installations, preserving valuable rack unit space while accommodating high-outlet-count configurations for dense server, storage, and networking equipment. Its metered intelligence goes beyond simple outlet counting: the onboard microcontroller continuously samples electrical parameters, flags threshold violations via configurable alarms, and logs consumption data to support chargeback reporting and energy efficiency audits. The unit communicates over a dedicated network management card interface compatible with APC's NMC ecosystem, allowing SNMP, Modbus, and web-based access without occupying a separate rack unit.

Targeted at IT infrastructure teams operating mission-critical facilities, the APDU9101M addresses the growing demand for per-rack power accountability in colocation, enterprise edge, and hyperscale-adjacent deployments. Its single-phase design simplifies integration into standard branch circuit environments while the 11.0 kW capacity supports fully loaded modern high-density racks. Onboard environmental monitoring extends situational awareness beyond electrical parameters to include temperature and humidity conditions at the rack level, making this unit a consolidation point for both power and physical environment data.

Ideal for

  • High-density enterprise data center racks requiring real-time inlet power metering and threshold-based alerting for capacity management
  • Colocation deployments where per-rack energy consumption must be logged and reported for tenant chargeback and SLA compliance
  • Edge computing installations demanding remote power monitoring and environmental sensing without dedicated on-site IT staff
  • DCIM integration projects leveraging EcoStruxure IT to correlate rack-level power data with cooling and asset management workflows
  • Data center consolidation audits requiring historical kWh consumption records to validate power utilization effectiveness (PUE) improvements
  • Regulated industries needing documented power usage reporting at the rack level to satisfy internal governance and environmental compliance requirements

Technical specifications

ManufacturerSchneider Electric
BrandAPC by Schneider Electric
Manufacturer Part NumberAPDU9101M
Product SeriesNetShelter Rack PDU Advanced
PDU TypeMetered (Inlet-level metering)
Phase ConfigurationSingle-phase
Maximum Load11.0 kW
Input Voltage208/230 V AC
Input Frequency50/60 Hz
Input ConnectionIEC 309 32A blue 2P+E
Metering GranularityInlet-level: current (A), voltage (V), active power (W/kW), apparent power (VA/kVA), energy (kWh)
Local DisplayIntegrated LED display for real-time electrical parameter readout
Network InterfaceDedicated RJ-45 network management port (NMC compatible)
Supported ProtocolsSNMP v1/v2c/v3, Modbus TCP, HTTP/HTTPS, SSH, Telnet
Environmental MonitoringOnboard temperature and humidity sensor included
Form Factor0U vertical rack mount
Operating Temperature0 °C to 45 °C
Operating Relative Humidity5% to 95% non-condensing
EcoStruxure IT CompatibleYes
Regulatory ComplianceCE, RoHS

Available from Omnixon Global. Submit an RFQ and our team will confirm configuration and availability for your order.

Technical Specifications

BrandSchneider Electric
CategoryRack PDUs
SKUSCHN-APDU9101M
Part NumberAPDU9101M
ConditionNew
Manufacturer Part NumberAPDU9101M
Product SeriesNetShelter Rack PDU Advanced
PDU TypeMetered (Inlet-level metering)
Phase ConfigurationSingle-phase
Maximum Load11.0 kW
Input Voltage208/230 V AC
Input Frequency50/60 Hz
Input ConnectionIEC 309 32A blue 2P+E
Metering GranularityInlet-level: current (A), voltage (V), active power (W/kW), apparent power (VA/kVA), energy (kWh)
Local DisplayIntegrated LED display for real-time electrical parameter readout
Network InterfaceDedicated RJ-45 network management port (NMC compatible)
Supported ProtocolsSNMP v1/v2c/v3, Modbus TCP, HTTP/HTTPS, SSH, Telnet
Environmental MonitoringOnboard temperature and humidity sensor included
Form Factor0U vertical rack mount
Operating Temperature0 °C to 45 °C
Operating Relative Humidity5% to 95% non-condensing
EcoStruxure IT CompatibleYes
Regulatory ComplianceCE, RoHS

Frequently Asked Questions about APC NetShelter Rack PDU Advanced Metered 11.0kW Single-Phase

What does the APC NetShelter Rack PDU Advanced Metered 11.0kW Single-Phase do?

The APC NetShelter Rack PDU Advanced Metered 11.0kW Single-Phase delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.

What are the headline specs of the APC NetShelter Rack PDU Advanced Metered 11.0kW Single-Phase?

Key specifications for the APC NetShelter Rack PDU Advanced Metered 11.0kW Single-Phase: new condition; manufacturer Schneider Electric; brand APC by Schneider Electric; manufacturer part number APDU9101M; product series NetShelter Rack PDU Advanced; pdu type Metered (Inlet-level metering); phase configuration Single-phase. Manufacturer part number APDU9101M. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.