APC by Schneider Electric NetShelter Rack PDU Advanced, Metered by Outlet with Switching, 3-phase, 11kW, 400V, 42 C13 & 6 C19

APC by Schneider Electric NetShelter Rack PDU Advanced, Metered by Outlet with Switching, 3-phase, 11kW, 400V, 42 C13 & 6 C19

Brand: APC | Category: Rack PDUs

SKU: APDU10150SM24 | Part #: APDU10150SM24 | MPN: APDU10150SM24

Contact for Pricing — Request a Quote

Request a Quote Contact Us

About the APC by Schneider Electric NetShelter Rack PDU Advanced, Metered by Outlet with Switching, 3-phase, 11kW, 400V, 42 C13 & 6 C19

The APC NetShelter APDU10150SM24 is a 3-phase, 11kW rack PDU with per-outlet switching and metering across 48 outlets at 400V.

At a glance — key specifications

Form FactorRack
Part NumberAPDU10150SM24
ManufacturerAPC
CommunicationUSB, RS-232, SNMP / NMC card

Perfect for

  • Server racks (single or paired)
  • Network and storage closets
  • Edge / branch IT
  • Small to mid-size datacentre rooms
  • Critical workstations and lab equipment

Request a quote for the APC by Schneider Electric NetShelter Rack PDU Advanced, Metered by Outlet with Switching, 3-phase, 11kW, 400V, 42 C13 & 6 C19

Submit your quantity, destination country, and required lead time below. Our pre-sales team responds within 48 hours with confirmed competitive quoting, availability, and matching support contract options.

Request a Quote →

Product information is provided for B2B procurement guidance. All trademarks are property of their respective owners.

Technical Specifications

BrandAPC
CategoryRack PDUs
SKUAPDU10150SM24
Part NumberAPDU10150SM24
ConditionNew
Form FactorRack
CommunicationUSB, RS-232, SNMP / NMC card
Manufacturer Part NumberAPDU10150SM24
Input Voltage400V (3-phase)
Power Capacity11 kW
Outlet Configuration42 x C13 & 6 x C19
Outlet Count48
Metering TypeMetered by outlet with switching
Management InterfaceEthernet (Web UI / SNMP)
Communication PortsUSB, RJ45 Ethernet, RS-232
Remote Power ControlPer-outlet and group switching
Environmental MonitoringTemperature, humidity, and power metrics
Rack Mount2U
Operating Temperature Range0–40°C
Overcurrent ProtectionCircuit breakers and surge protection

Frequently Asked Questions about APC by Schneider Electric NetShelter Rack PDU Advanced, Metered by Outlet with Switching, 3-phase, 11kW, 400V, 42 C13 & 6 C19

How long will this UPS run my load?

Runtime is load-dependent. Most enterprise UPS at 50% load deliver 8-12 minutes battery on standard internal batteries. Add external battery packs (XL / RBC modules) to extend to 30-60 minutes if you need ride-through past short utility blips.

Can it integrate with VMware vCenter / Veeam for graceful shutdown?

Yes — we ship the SNMP / Network Management Card (NMC) alongside the UPS, plus shutdown agents that integrate with VMware PowerChute, Veeam, NetApp ONTAP, and standard SNMP traps for orchestration platforms.