Brand: APC | Category: Rack PDUs
SKU: AP6032A | Part #: AP6032A | MPN: AP6032A
Contact for Pricing — Request a Quote
The APC AP6032A is a Basic single-phase rack power distribution unit (PDU) for distributing power to equipment in a server or network rack. It mounts horizontally or vertically in a 0U/1U configuration and provides four C19 outlets, with a 3.65 m input cable terminated in an IEC 60309 plug.
The unit accepts a nominal input of 200-240 V at 50-60 Hz and supports a maximum current of 32 A, with a maximum power of 7680 W and a load capacity of 7680 VA. As a Basic PDU, it handles straightforward power distribution. The black unit operates at 0-50 °C and 5-95% relative humidity, and can be stored at -15 to 60 °C.
With its C19 outlets and 32 A rating, the AP6032A suits data centre and server room racks that host higher-draw devices such as servers, storage systems and network switches.
Send the part number through our RFQ form and our team will reply within 48 hours.
| Brand | APC |
| Category | Rack PDUs |
| SKU | AP6032A |
| Part Number | AP6032A |
| Condition | New |
| AC outlet types | C19 coupler |
| Power plug | IEC 60309 |
| AC outlets quantity | 4 AC outlet(s) |
| Cable length | 3.65 m |
| Maximum power | 7680 W |
| Maximum input current per phase | 32 A |
| Load capacity | 7680 VA |
| Nominal output voltage | 200-240 V |
| Maximum current | 32 A |
| AC input frequency | 50 - 60 Hz |
| Nominal input voltage | 200-240 V |
| Product colour | Black |
| Mounting | Horizontal/Vertical |
| Rack capacity | 0U/1U |
| Type | Single-phase |
| PDU types | Basic |
| Operating relative humidity (H-H) | 5 - 95% |
| Storage relative humidity (H-H) | 5 - 95% |
| Storage temperature (T-T) | -15 - 60 °C |
| Operating temperature (T-T) | 0 - 50 °C |
| Weight | 2.78 kg |
| Height | 43.8 mm |
| Depth | 9.29 mm |
| Width | 4.36 mm |
| Certification | VDE, CE |
| Compliance certificates | RoHS |
The APC AP6032A Rack PDU, Basic, 0U/1U, 220-240V, 32A, (4) C19, EMEA/ASIA delivers conditioned, backed-up power for server rooms and data-center racks. Use cases include short-term ride-through during grid sag/spike events, graceful shutdown of critical compute, and runtime extension via external battery packs.
Key specifications for the APC AP6032A Rack PDU, Basic, 0U/1U, 220-240V, 32A, (4) C19, EMEA/ASIA: new condition; ac outlet types C19 coupler; power plug IEC 60309; ac outlets quantity 4 AC outlet(s); cable length 3.65 m; maximum power 7680 W; maximum input current per phase 32 A. Manufacturer part number AP6032A. For the full datasheet with electrical, environmental, and compliance details, contact our pre-sales engineering team.