About the Acer Altos UPS 1500VA Rack/Tower UPS

The Acer Altos UPS 1500VA Rack/Tower UPS from Acer is enterprise-grade UPS & Power Protection hardware built for data centers. Dual-conversion online UPS delivering 1500VA of conditioned power for rack and tower deployments in enterprise IT and medical imaging environments. Available in brand new condition. Acer ups & power protection products are trusted by enterprises and data centers worldwide. Available from Omnixon Global. Contact our sales team to request a quote.

Technical Specifications

BrandAcer
CategoryUPS & Power Protection
SKUACER-APCUPSRT1500
Part NumberAPC-UPS-RT1500
ConditionNew
Product LineAltos UPS
Model1500VA
UPS TypeDual-conversion online (VFI SS 111)
TopologyTrue online with rectifier, inverter, and static bypass
Input Voltage Range176–264 VAC (adjustable tolerance window)
Input Frequency50/60 Hz ±5 Hz (auto-sensing)
Output Voltage220/230/240 VAC (selectable) ±2%
Output Frequency50/60 Hz synchronized to inverter ±0.5 Hz
VA Rating1500 VA
Power Output1050 W at 0.7 power factor; up to 1500 W at 1.0 pf (resistive load)
Efficiency (Online Mode)≥92% (typical at 50% load)
Transfer Time (Mains to Battery)<1 ms (zero in online mode)
Battery TypeSealed lead-acid (VRLA), user-replaceable
Backup Runtime at Full Load8–12 minutes (dependent on battery configuration)
Runtime at 50% Load15–20 minutes
External Battery ModulesSupported; extends runtime to 45+ minutes at rated load
Deployment OptionsRack-mount (2U) or tower/pedestal configuration
CoolingForced-air convection with thermal management
Input Connectors1× IEC 60320 C20 (three-phase optional)
Output Connectors4× IEC 60320 C13 + 1× IEC 60320 C19 (rear; front optional)
Remote ManagementSNMP agent, Modbus TCP/IP; dry relay contacts for generator integration
Display16×2 LCD with real-time status and event logging
Audible AlarmMute-able; selectable alert tones for AC loss, low battery, overload conditions
Surge Protection6 kVA peak transient immunity on input and output
Noise Level<65 dB(A) at 1 meter (full-load online operation)
Dimensions (Tower)400 mm H × 150 mm W × 350 mm D
Dimensions (2U Rack)88 mm H × 483 mm W × 450 mm D
Weight22 kg (battery included; rackmount adds ~2 kg)
Operating Temperature0–40°C (25°C nominal for full-load rating)
Operating Humidity20–80% RH (non-condensing)
EMC ComplianceCE (EN 62040-1, -2); FCC Class A
Safety StandardsIEC 62040-1 (UPS safety); IEC 60950-1 (electrical safety)
Launch DateQ4 2023